Comparative Assessment of Percutaneous Left-Atrial Appendage Occlusion (LAAO) Devices—A Single Center Cohort Study

Author:

Kayvanpour Elham12ORCID,Kothe Max1,Kaya Ziya12ORCID,Pleger Sven1,Frey Norbert12,Meder Benjamin123,Sedaghat-Hamedani Farbod12ORCID

Affiliation:

1. Department of Internal Medicine III, Heidelberg University, 69120 Heidelberg, Germany

2. DZHK (German Centre for Cardiovascular Research), 69120 Heidelberg, Germany

3. Department of Genetics, Stanford Genome Technology Center, Stanford University School of Medicine, Stanford, CA 94305, USA

Abstract

Background: Percutaneous left-atrial appendage closure (LAAC) is an established method for preventing strokes in patients with atrial fibrillation, offering an alternative to oral anticoagulation. Various occluder devices have been developed to cater to individual anatomical needs and ensure a safe and effective procedure. In this retrospective, monocentric cohort study, we compare different LAAO devices with respect to clinical outcomes, LAA sealing properties, and device-related complications. Methods: We conducted a retrospective analysis of 270 patients who underwent percutaneous LAA closure in our center between 2009 and 2023. Patient data were extracted from medical records, including gender, age at implantation, indication, device type and size, laboratory values, LAA anatomy, periprocedural complications, ECG parameters, transthoracic and transesophageal echocardiography parameters (TTE and TEE), as well as medication at discharge. Moreover, fluoroscopy time and implantation duration, as well as post-implantation clinical events up to 1 year, were collected. Endpoints were bleeding events, recurrent stroke, thrombi on devices, and death. Results: The implanted devices were the Watchman 2.5, Watchman FLX, Amplatzer Cardiac Plug (ACP), and Amulet. The procedural success rate was 95.7% (n = 265), with cactus anatomy posing the most challenges across all devices. The mean patient age was 75.5 ± 7.7 years, with 64.5% being male. The median CHA2DS2-VASc score was 4.8 ± 1.5 and the median HAS-BLED score was 3.8 ± 1.0. Indications for LAA closure included past bleeding events and elevated bleeding risk. Periprocedural complications were most commonly bleeding at the puncture site, particularly after ACP implantation (p = 0.014). Significant peridevice leaks (PDL) were observed in 21.4% of simple sealing mechanism devices versus 0% in double sealing mechanism devices (p = 0.004). Thrombi were detected on devices in six patients, with no subsequent ischemic stroke or thromboembolic event. Comparative analysis revealed no significant differences in the occurrence of stroke, transient ischemic attack (TIA), thromboembolic events, device-related thrombi, or mortality among different device types. A 62.3% relative risk reduction in thromboembolic events and 38.6% in major bleedings could be observed over 568.2 patient years. Conclusions: In summary, our study highlights the efficacy and safety of LAA closure using various occluder devices despite anatomical challenges. Our long-term follow-up findings support LAA closure as a promising option for stroke prevention in selected patient cohorts. Further research is needed to refine patient selection criteria and optimize outcomes in LAA closure procedures.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3