This paper studies the effects of compression, deformation, and the contact area in the membrane electrode assembly (MEA). The electrical impedance of fuel cell stacks due to the assembly of the metallic bipolar plates is also considered. According to decades-long fuel cell (FC) assembly experience, an increase in compression force can result in adequate contact resistance, but excessive compression may cause extra contact resistance and damage to the MEA structure. The study suggests a design for improving the performance of the FC stack by proposing different fillet radii metallic bipolar plates. It is found that the appropriate fillet radius reduces contact resistance by 13% and avoids the accumulation of compression, thereby maintaining contact resistance at adequate levels. The current design proposes a simple and effective method to minimize the dimension tolerance of single fuel cell units and support sufficient compression.