Comparison of Depolarization and Repolarization Parameters in Left vs. Right Ventricular Septal Pacing—An Intraprocedural Electrocardiographic Study

Author:

Pestrea Catalin123ORCID,Cicala Ecaterina1,Ivascu Madalina1,Gherghina Alexandra1,Ortan Florin1,Pop Dana23

Affiliation:

1. Department of Interventional Cardiology, Brasov County Clinical Emergency Hospital, 500326 Brasov, Romania

2. 5th Department of Internal Medicine, Faculty of Medicine, “Iuliu Hațieganu” University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania

3. Department of Cardiology, Clinical Rehabilitation Hospital, 400347 Cluj-Napoca, Romania

Abstract

Compared with conventional right ventricular septal pacing (RVSP), several studies have shown a net clinical benefit of left bundle branch area pacing (LBBAP) in terms of ejection fraction preservation and reduced hospitalizations for heart failure. The purpose of this study was to compare acute depolarization and repolarization electrocardiographic parameters between LBBAP and RVSP in the same patients during the LBBAP implant procedure. We prospectively included 74 consecutive patients subjected to LBBAP from 1 January to 31 December 2021 at our institution in the study. After the lead was placed deep into the ventricular septum, unipolar pacing was performed and 12-lead ECGs were recorded from the distal (LBBAP) and proximal (RVSP) electrodes. QRS duration (QRSd), left ventricular activation time (LVAT), right ventricular activation time (RVAT), QT and JT intervals, QT dispersion (QTd), T-wave peak-to-end interval (Tpe), and Tpe/QT were measured for both instances. The final LBBAP threshold was a 0.7 ± 0.31 V at 0.4 ms duration with a sensing threshold of 10.7 ± 4.1 mV. RVSP produced a significantly larger QRS complex than the baseline QRS (194.88 ± 17.29 ms vs. 141.89 ± 35.41 ms, p < 0.001), while LBBAP did not significantly change the mean QRSd (148.10 ± 11.52 ms vs. 141.89 ± 35.41 ms, p = 0.135). LVAT (67.63 ± 8.79 ms vs. 95.89 ± 12.02 ms, p < 0.001) and RVAT (80.54 ± 10.94 ms vs. 98.99 ± 13.80 ms, p < 0.001) were significantly shorter with LBBAP than with RVSP. Moreover, all the repolarization parameters studied were significantly shorter in LBBAP than in RVSP (QT—425.95 ± 47.54 vs. 487.30 ± 52.32; JT—281.85 ± 53.66 vs. 297.69 ± 59.02; QTd—41.62 ± 20.07 vs. 58.38 ± 24.44; Tpe—67.03 ± 11.19 vs. 80.27 ± 10.72; and Tpe/QT—0.158 ± 0.028 vs. 0.165 ± 0.021, p < 0.05 for all), irrespective of the baseline QRS morphology. LBBAP was associated with significantly better acute depolarization and repolarization electrocardiographic parameters compared with RVSP.

Publisher

MDPI AG

Subject

Pharmacology (medical),General Pharmacology, Toxicology and Pharmaceutics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3