Integrating CAD and 3D-Printing Techniques to Construct an In Vitro Laser Standard Treatment Platform for Evaluating the Effectiveness of Sterilization by Er:YAG Laser in Peri-Implant Intra-Bony Defects

Author:

Chang Shih-HaoORCID,Mei Hsiang-I,Lin Chun-LiORCID

Abstract

This study established an in vitro model mimicking clinical peri-implant intra-bony defects. We investigated the effect of access limitation and the bactericidal effectiveness of erbium-doped yttrium, aluminum and garnet (Er:YAG) laser irradiation in shallow and deep peri-implant defects at different tooth positions. Reverse engineering, computer-aided design (CAD), and 3D-printing techniques were integrated to establish physical peri-implant intra-bony defect models at mandibular central incisor, first premolar, and first molar positions with shallow (2 mm depth) or deep (6 mm depth) defects and with 1.5 mm and 1.8 mm widths at the bottom and crestal portions of the alveolar process, respectively. Three-dimensional printed suites at the corresponding implant sites replaced experimental implant specimens for the investigation of bacterial adhesion in individuals. Dental implants with diameters of 3, 4 and 5 mm were utilized at the mandibular incisor, premolar, and molar positions, respectively. Bacterial adhesion of Gram (–) Escherichia coli on the exposed implant surfaces prior to sterilization was assessed. Sterilization with shallow and deep intra-bony defects was investigated by measuring the reduction of residual viable bacteria on implants after 60 s of irradiation with an Er:YAG laser. The adhesion rate of Gram (–) Escherichia coli on the investigated implant surfaces ranged from 1% to 3% (1.76 ± 1.25%, 2.19   ±   0.75% and 2.66   ±   1.26% for 3, 4, and 5 mm implants, respectively). With shallow peri-implant bony defects, the Er:YAG laser sterilization rates were 99.6 ± 0.5%, 99.3   ±   0.41% and 93.8 ± 7.65% at mandibular incisor, premolar, and molar positions, respectively. Similarly, sterilization rates in deep peri-implant defects were 99 ± 1.35%, 99.1 ± 0.98% and 97.14 ± 2.57%, respectively. A 3D-printed model with replaceable implant specimens mimicking human peri-implant intra-bony defects was established and tested in vitro. This investigation demonstrated effective sterilization using Er:YAG laser irradiation in both shallow and deep peri-implant intra-bony defects at different positions and diameters of dental implants.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3