Reconstruction of Complex Zygomatic Bone Defects Using Mirroring Coupled with EBM Fabrication of Titanium Implant

Author:

Moiduddin KhajaORCID,Hammad Mian SyedORCID,Umer UsamaORCID,Ahmed NaveedORCID,Alkhalefah Hisham,Ameen WadeaORCID

Abstract

Reconstruction of zygomatic complex defects is a surgical challenge, owing to the accurate restoration of structural symmetry as well as facial projection. Generally, there are many available techniques for zygomatic reconstruction, but they hardly achieve aesthetic and functional properties. To our knowledge, there is no such study on zygomatic titanium bone reconstruction, which involves the complete steps from patient computed tomography scan to the fabrication of titanium zygomatic implant and evaluation of implant accuracy. The objective of this study is to propose an integrated system methodology for the reconstruction of complex zygomatic bony defects using titanium comprising several steps, right from the patient scan to implant fabrication while maintaining proper aesthetic and facial symmetry. The integrated system methodology involves computer-assisted implant design based on the patient computed tomography data, the implant fitting accuracy using three-dimensional comparison techniques, finite element analysis to investigate the biomechanical behavior under loading conditions, and finally titanium fabrication of the zygomatic implant using state-of-the-art electron beam melting technology. The resulting titanium implant has a superior aesthetic appearance and preferable biocompatibility. The customized mirrored implant accurately fit on the defective area and restored the tumor region with inconsequential inconsistency. Moreover, the outcome from the two-dimensional analysis provided a good accuracy within 2 mm as established through physical prototyping. Thus, the designed implant produced faultless fitting, favorable symmetry, and satisfying aesthetics. The simulation results also demonstrated the load resistant ability of the implant with max stress within 1.76 MPa. Certainly, the mirrored and electron beam melted titanium implant can be considered as the practical alternative for a bone substitute of complex zygomatic reconstruction.

Funder

Deanship of Scientific Research, King Saud University

Publisher

MDPI AG

Subject

General Materials Science,Metals and Alloys

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3