Abstract
In this contribution, a harmonic domain (HD) model of grid-connected photovoltaic (PV) generation systems is proposed. The topology of the PV generation system contains a PV array connected to a DC/DC converter and a DC/AC converter, coupled to the grid through a filter. The individual components of the PV system are modeled in the HD. The PV array is represented as a Thevenin equivalent, whereas the DC/DC converter and the DC/AC converter are represented in the HD using switching function matrices. The periodic steady-state solution of the PV system is obtained through simple matrix/vector operations. The results obtained by the proposed model are validated against the response obtained with the PSCAD/EMTDC® simulator, widely accepted by the power industry.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Reference28 articles.
1. Distributed Power Generation: Planning and Evaluation;Willis,2000
2. Solarpark Ammerland, Oldenburg, Niedersachsen, Deutschland
www.martin-bucher.de
3. Ross River Solar Farm, Queensland, Australia
www.rossriversolarfaarm.com.au
4. Grid-connected photovoltaic power systems: Technical and potential problems—A review
5. Modeling and simulation of a grid-connected PV generation system for electromagnetic transient analysis
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献