Patient Ability to Use Old versus New/Modified Model Adrenaline Autoinjection Emergency Medical Devices for Anaphylaxis in Prehospital Setting: A Systematic Review and Meta-Analysis

Author:

Chow Wei LeongORCID,Yazid Mohd BoniamiORCID,Norhayati Mohd NoorORCID,Md Noh Abu YazidORCID,Rahman Andey

Abstract

Background: The goal of this study was to determine the individual’s ability to use new/modified model AAI compared to old model AAIs devices for anaphylaxis. Methods: The protocol was established a priori and published on PROSPERO (CRD42021229691) and was conducted based on PRISMA guidelines. MEDLINE and CENTRAL were searched until 31 January 2021. Only RCTs were included in this review. Primary studies comparing old model AAI to new/modified model AAI emergency medical devices were included. Primary outcomes included number of successful administrations, and number of individuals to complete all steps. Secondary outcomes included successful removal of device safety guards, placement of correct end of the device against the thigh and holding of the device in place for adequate time after administration; the frequency of an adverse event (digital injection); individual preferences in terms of size, individual preference in terms of ease for carrying, overall patient preference; and the mean time of delivery. Results: Overall, seven trials consisting of 1359 patients were analyzed. Reporting of adverse events was limited to digital injection, which was significantly higher in the old model AAI (RR 6.90, 95% CI 3.27 to 14.57; I2 statistic = 0%; p < 0.001; four trials, 610 participants; high quality evidence). No significant difference was found regarding successful administration between the old model AAI and new/modified model AAI (RR 0.76, 95% CI 0.52 to 1.11; I2 statistic = 96%; p = 0.16; seven trials, 2196 participants; low quality evidence). Conclusions: We cannot make any new recommendations on the effectiveness of different models of AAIs regarding successful administration. However, considering the aspect of safety, we think that mew/modified model AAI can be chosen as the old model AAI was associated with a higher frequency of the adverse event (digital injection).

Publisher

MDPI AG

Subject

Health Information Management,Health Informatics,Health Policy,Leadership and Management

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3