Preliminary Insights into the Diagnostic Accuracy of the Modified Arm Care Screen Test for Overhead Athletes: An On-Field Tool for Injury Prevention

Author:

Paraskevopoulos Eleftherios12ORCID,Kottaridis Fotis-Marios2,Moutzouri Maria1,Koumantakis George A.1ORCID,Antonakis-Karamintzas Dimitrios3,Tsolakis Charilaos34ORCID,Koulouvaris Panagiotis3ORCID,Christakou Anna2ORCID,Papandreou Maria1

Affiliation:

1. Department of Physiotherapy, University of West Attica, 12243 Athens, Greece

2. Department of Physiotherapy, University of Peloponnese, 23100 Sparta, Greece

3. 1st Department of Orthopaedic Surgery, School of Medicine, National and Kapodistrian University of Athens, 12462 Athens, Greece

4. Sports Performance Laboratory, School of Physical Education & Sports Science, National and Kapodistrian University of Athens, 17237 Athens, Greece

Abstract

Background: The Arm Care Screen was developed to detect musculoskeletal limitations that could affect performance or even increase the risk for shoulder injuries in overhead athletes. This study aimed to assess the discriminant validity of the modified Arm Care Screen in overhead athletes. Methods: Sixty-two overhead athletes (mean age: 24.5 ± 4.2 years) were recruited. The athletes underwent a comprehensive Arm Care Screen evaluation, including reciprocal shoulder mobility, total body rotation, lower body diagonal reach, and rotary stability assessments. Ten different musculoskeletal measurements were independently measured by two physical therapists. Results: The modified Arm Care Screen showed moderate to strong associations (phi values ranged from 0.273 to 0.905) with the respective musculoskeletal range of motion and balance measurements. Sensitivity ranged from 81.25% to 88.57%, indicating a high true positive rate, and specificity ranged from 43.75% to 94.44%, indicating a moderate to strong positive rate. Positive and negative likelihood ratios ranged from 1.48 to 15.92 and 0.12 to 0.38, respectively. The positive and negative predictive value ranged from 58.14% to 92% and from 73.68% to 93.18%, respectively. The accuracy of the modified ACS ranged from 62.90% to 91.94%. Conclusion: The modified Arm Care Screen demonstrated promising diagnostic accuracy in identifying significant movement restrictions.

Publisher

MDPI AG

Subject

Health Information Management,Health Informatics,Health Policy,Leadership and Management

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3