Abstract

Longitudinal ventilation and smoke extraction by shaft are common smoke control methods in road tunnel fires. Tunnels often adopt one of these methods in practical engineering. However, it may have a better effect to adopt the method of mixing the two smoke exhaust methods together, which has not been revealed in the previous literature. Hence, the coupled effects of longitudinal ventilation and natural ventilation with shafts on the smoke control in tunnel fires were studied in this work. Numerical simulation was carried out considering different longitudinal ventilation velocities (0–4 m/s) and 4 kinds of typical shaft arrangements (shaft lengths range of 3–12 m, shaft intervals range of 27–60 m). The smoke spread length and smoke exhaust efficiency were analyzed systematically. Results show that (1) with the increase in longitudinal ventilation velocity, the total smoke spread length firstly decreases (V < 1 m/s) and then keeps almost constant (1 m/s < V < 2 m/s), finally increasing significantly (V > 2 m/s). (2) The length of the dangerous area (over 60 °C) at human height is basically 0 for all cases (except for Scenario 4 of shaft arrangement) when the longitudinal ventilation velocity is less than 2 m/s. (3) The CO smoke flow rate through the shaft is relatively high when the longitudinal ventilation velocity is within the range of 1–2 m/s for 4 kinds of shaft arrangement scenarios. Factors such as smoke spread and smoke exhausted through the shaft are comprehensively considered to judge smoke exhaust performance. The following conclusions can be drawn: when the ventilation velocity ranges from 1–2 m/s, it has a positive impact on the smoke control in tunnel fires with natural ventilation with shafts. When the ventilation velocity exceeds 2 m/s, the total smoke spread length and the length of the danger area increase, and the smoke stratification becomes worse, which brings inconvenience to rescue work. The results can provide reference for the design of fire protection in tunnels.

Funder

National Natural Science Foundation of China

Fundamental Research Funds for the Central Universities

Publisher

MDPI AG

Subject

Earth and Planetary Sciences (miscellaneous),Safety Research,Environmental Science (miscellaneous),Safety, Risk, Reliability and Quality,Building and Construction,Forestry

Reference32 articles.

1. Large Eddy Simulation of stack effect on natural smoke exhausting effect in urban road tunnel fires;Ji;Int. J. Heat Mass Transf.,2013

2. Theoretical and numerical study on critical velocity and driving force for preventing smoke backlayering in a connection roadway fire of coal mines;Yao;Tunn. Undergr. Space Technol.,2022

3. A Discussion on the Control Standards for Smoke CO Concentration during Fires in High-altitude Railway Tunnels;Wang;Mod. Tunn. Technol.,2022

4. Hu, L.H. (2006). Studies on Thermal Physics of Smoke Movement in Tunnel Fires. [Ph.D. Thesis, University of Science and Technology of China].

5. Control of smoke flow in tunnel fires using longitudinal ventilation systems—A study of the critical velocity;Wu;Fire Saf. J.,2000

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3