Toward Isolation of Palytoxins: Liquid Chromatography Coupled to Low- or High-Resolution Mass Spectrometry for the Study on the Impact of Drying Techniques, Solvents and Materials

Author:

Mazzeo Antonia,Varra Michela,Tartaglione LucianaORCID,Ciminiello Patrizia,Zendong Zita,Hess PhilippORCID,Dell’Aversano CarmelaORCID

Abstract

Palytoxin (PLTX) and its congeners are emerging toxins held responsible for a number of human poisonings following the inhalation of toxic aerosols, skin contact, or the ingestion of contaminated seafood. Despite the strong structural analogies, the relative toxic potencies of PLTX congeners are quite different, making it necessary to isolate them individually in sufficient amounts for toxicological and analytical purposes. Previous studies showed poor PLTX recoveries with a dramatic decrease in PLTX yield throughout each purification step. In view of a large-scale preparative work aimed at the preparation of PLTX reference material, we have investigated evaporation as a critical—although unavoidable—step that heavily affects overall recoveries. The experiments were carried out in two laboratories using different liquid chromatography-mass spectrometry (LC-MS) instruments, with either unit or high resolution. Palytoxin behaved differently when concentrated to a minimum volume rather than when evaporated to complete dryness. The recoveries strongly depended on the solubility as well as on the material of the used container. The LC-MS analyses of PLTX dissolved in aqueous organic blends proved to give a peak intensity higher then when dissolved in pure water. After drying, the PLTX adsorption appeared stronger on glass surfaces than on plastic materials. However, both the solvents used to dilute PLTX and that used for re-dissolution had an important role. A quantitative recovery (97%) was achieved when completely drying 80% aqueous EtOH solutions of PLTX under N2-stream in Teflon. The stability of PLTX in acids was also investigated. Although PLTX was quite stable in 0.2% acetic acid solutions, upon exposure to stronger acids (pH < 2.66), degradation products were observed, among which a PLTX methyl-ester was identified.

Funder

Programme STAR Linea 1 2013

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Toxicology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3