Biomechanical Testing of Two-Unit Bridges and a Comparison of Replacement Retention Depending on a Cementation Medium, Replacement Position, and Gap Size

Author:

Findrik Balogová AlenaORCID,Rajťúková ViktóriaORCID,Chromý Ľuboš,Somoš Andrej,Ižaríková Gabriela,Hudák Radovan

Abstract

Dental replacements are placed between the abutment teeth. The exceptions are two-unit bridges, as they are supported by a single tooth prepared only on one side of the missing tooth. The presented study deals with an analysis of a pressure force action on two-unit bridges placed in the frontal part (20 samples), where the pressure action is lower, and in the distal part (20 samples), where the pressure action is higher. A CAD program by 3Shape was used for digital designing with two different gap settings, 10 μm (20 samples) and 30 μm (20 samples). Two-unit bridges were attached to the prepared tooth using two types of dental cement (20/20 samples), which were selected for their physical and bioactive properties. All two-unit bridges (a total of 80 samples) were fabricated from CoCr alloys on Mlab cusing R by applying the Selective Laser Melting (SLM) technology. Mechanical testing was performed using the Inspekt5 table blue. The obtained data were used to verify the hypotheses—a difference between both types of cement (A ≠ B), a difference between the frontal and distal two-unit bridges (F ≠ D) and a difference between the gap sizes (10 ≠ 30). To confirm the given theories, data were statistically evaluated using the F-test and subsequent t-tests. The resulting p-value was compared with the level of significance (α = 0.05). A statistical evaluation revealed a significant difference between the compared groups; however, no explicit correlation between the individual groups of specimens was identified.

Funder

Slovak Research and Development Agency

Publisher

MDPI AG

Subject

Biomedical Engineering,Biomaterials

Reference35 articles.

1. Mechanical properties of dental Co-Cr alloys fabricated via casting and Selective Laser Melting;Dolgov;Mater. Sci. Non-Equilib. Phase Transform.,2016

2. Mechanical performance, corrosion and tribological evaluation of a Co–Cr–Mo alloy processed by MIM for biomedical applications;Herranz;J. Mech. Behav. Biomed. Mater.,2020

3. Tresca stress study of CoCrMo-on-CoCrMo bearings based on body mass index using 2D computational model;Ammarullah;J. Tribol.,2022

4. Viderščak, D., Schauperl, Z., Šolić, S., Ćatić, A., Godec, M., Kocijan, A., Paulin, I., and Donik, Č. (2021). Additively Manufactured Commercial Co-Cr Dental Alloys: Comparison of Microstructure and Mechanical Properties. Materials, 14.

5. Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology;Quante;Dent. Mater.,2008

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献