Reflection-Boosted Wearable Ring-Type Pulse Oximeters for SpO2 Measurement with High Sensitivity and Low Power Consumption

Author:

Joo Min Gyu1,Lim Dae Hyeong23,Park Kyu-Kwan1,Baek Jiwon1,Choi Jong Min3,Baac Hyoung Won1ORCID

Affiliation:

1. Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea

2. Department of Digital Media Communication Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea

3. Health H/W R&D Group, Samsung Electronics, Suwon 16677, Republic of Korea

Abstract

In this study, we demonstrated a Monte Carlo simulation to model a finger structure and to calculate the intensity of photons passing through tissues, in order to determine optimal angular separation between a photodetector (PD) and a light-emitting diode (LED), to detect SpO2. Furthermore, our model was used to suggest a mirror-coated ring-type pulse oximeter to improve the sensitivity by up to 80% and improve power consumption by up to 65% compared to the mirror-uncoated structure. A ring-type pulse oximeter (RPO) is widely used to detect photoplethysmography (PPG) signals for SpO2 measurement during sleep and health-status monitoring. Device sensitivity and the power consumption of an RPO, which are key performance indicators, vary greatly with the geometrical arrangement of PD and LED within the inner surface of an RPO. We propose a reflection-boosted design of an RPO to achieve both high sensitivity and low power consumption, and determine an optimal configuration of a PD and LED by performing a 3D Monte Carlo simulation and confirming its agreement with experimental measurement. In order to confirm the reflection-boosted performance in terms of signal-to-noise ratio, R ratio, and perfusion index (PI), RPOs were fabricated with and without a highly reflective coating, and then used for SpO2 measurement from eight participants. Our simulation allows the numerical calculation of the intensity of photon passing and scattering through finger tissues. The reflection-boosted RPO enables reliable measurement with high sensitivity, resulting in less power consumption for the LED and longer device usage than conventional RPOs without any reflective coating, in order to maintain the same level of SNR and PI. Compared to the non-reflective reference RPO, the reflection-boosted RPO design greatly enhanced both detected light intensity (67% in dc and 322% in ac signals at a wavelength λ1 = 660 nm, and also 81% and 375% at λ2 = 940 nm, respectively) and PI (23.3% at λ1 and 25.5% at λ2). Thus, the reflection-boosted design not only enhanced measurement reliability but also significantly improved power consumption, i.e., by requiring only 36% and 30% power to drive the LED sources with λ1 and λ2, respectively, to produce the device performance of a non-reflective RPO reference. It is expected that our proposed RPO provides long-term monitoring capability with low power consumption and an enhanced PI for SpO2 measurement.

Funder

National Research Foundation of Korea

MSIT (Ministry of Science and ICT), Korea

Publisher

MDPI AG

Subject

Clinical Biochemistry,General Medicine,Analytical Chemistry,Biotechnology,Instrumentation,Biomedical Engineering,Engineering (miscellaneous)

Reference41 articles.

1. A review of machine learning techniques in photoplethysmography for the non-invasive cuff-less measurement of blood pressure;Kyriacou;Biomed. Signal Process. Control,2020

2. Mendelson, Y., Cheung, P.W., Neuman, M.R., Fleming, D.G., and Cahn, S.D. (1983). Advances in Experimental Medicine and Biology, Springer.

3. Forehead pulse oximetry compared with finger pulse oximetry and arterial blood gas measurement;Chang;J. Clin. Monit.,1988

4. Madhan, P.M., Nagarajan, V., and Das, S.R. (2015, January 2–4). Heart rate measurement from wearable photoplethysmographic sensor using spot and tracking methods. Proceedings of the International Conference on Communication and Signal Processing, Melmaruvathur, India.

5. Obstructive sleep apnea;Ho;Neurol. Int.,2011