Performance Evaluation of an Evacuated Tube Collector with a Low-Cost Diffuse Reflector

Author:

Schumann JulianORCID,Schiebler Bert,Giovannetti Federico

Abstract

In order to increase the overall solar energy gain of evacuated tube collectors, rear-side reflectors are used. In this way, the otherwise unused incident radiation between the tubes can be reflected back to the absorber, and the performance of the collector can be improved. In this paper, the use of a low-cost, diffusely reflecting, trapezoidal roof covering made from a galvanized metal sheet is investigated and compared to a high-quality, specularly reflecting plane reflector made of aluminum. For this purpose, ray-tracing analysis and TRNSYS simulations were carried out. In the ray-tracing analysis, the experimentally determined zero-loss collector efficiency η0 as well as the incident angle modifiers for each reflector can be reproduced with an error lower than 7.5%. Thermal system simulations show that the performance of both reflectors is comparable. The use of the low-cost reflector leads to an increase in annual collector output of around 30% compared to an increase with the specular reflector of around 33%. Considering a typical domestic hot water system, both reflectors enable an increase in the solar annual yield of approx. 11%.

Funder

German State of Lower Saxony and the Federal Ministry of Economics and Energy

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)

Reference27 articles.

1. Optimal tilt-angles of all-glass evacuated tube solar collectors

2. Guideline for Levelized Cost of Heat (LCoH) Calculations for Solar Thermal Applicationshttps://task54.iea-shc.org/Data/Sites/1/publications/A01-Info-Sheet--LCOH-for-Solar-Thermal-Applications.pdf

3. Solar Energy—Solar Thermal Collectors—Test Methods,2018

4. Development, Testing and Certification of Owens-Illinois Model SEC-601 Solar Energy Collector System—Final Report;Parker,1979

5. Analysis and Experimental Tests of a High-Performance Evacuated Tubular Collector;Beekley,1978