Normal ankle function provides a key contribution to everyday activities, particularly step/stair ascent and descent, where many falls occur. The rising to up-on-the-toes (UTT) 30 second test (UTT-30) is used in the clinical assessment of ankle muscle strength/function and endurance and is typically assessed by an observer counting the UTT movement completed. The aims of this study are: (i) to determine whether inertial measurement units (IMUs) provide valid assessment of the UTT-30 by comparing IMU-derived metrics with those from a force-platform (FP), and (ii) to describe how IMUs can be used to provide valid assessment of the movement dynamics/stability when performing a single UTT movement that is held for 5 s (UTT-stand). Twenty adults (26.2 ± 7.7 years) performed a UTT-30 and a UTT-stand on a force-platform with IMUs attached to each foot and the lumbar spine. We evaluate the agreement/association between IMU measures and measures determined from the FP. For UTT-30, IMU analysis of peaks in plantarflexion velocity and in FP’s centre of pressure (CoP) velocity was used to identify each repeated UTT movement and provided an objective means to discount any UTT movements that were not completed ‘fully’. UTT movements that were deemed to have not been completed ‘fully’ were those that yielded peak plantarflexion and CoP velocity values during the period of rising to up-on-the-toes that were below 1 SD of each participant’s mean peak rising velocity across their repeated UTT. The number of UTT movements detected by the IMU approach (23.5) agreed with the number determined by the FP (23.6), and each approach determined the same number of ‘fully’ completed movements (IMU, 19.9; FP, 19.7). For UTT-stand, IMU-derived movement dynamics/postural stability were moderately-to-strongly correlated with measures derived from the FP. Our findings highlight that the use of IMUs can provide valid assessment of UTT test(s).

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3