Label-Free Cyanobacteria Quantification Using a Microflow Cytometry Platform for Early Warning Detection and Characterization of Hazardous Cyanobacteria Blooms

Author:

Zhang Yushan1,Escobar Andres1,Guo Tianyi2,Xu Chang-Qing13

Affiliation:

1. Department of Biomedical Engineering, McMaster University, Hamilton, ON L8S 4L8, Canada

2. Forsee Instruments Ltd., Hamilton, ON L8P 0A1, Canada

3. Department of Engineering Physics, McMaster University, Hamilton, ON L8S 4L8, Canada

Abstract

The eutrophication of aquatic ecosystems caused by rapid human urbanization has led to an increased production of potentially hazardous bacterial populations, known as blooms. One of the most notorious forms of these aquatic blooms are cyanobacteria, which in sufficiently large quantities can pose a hazard to human health through ingestion or prolonged exposure. Currently, one of the greatest difficulties in regulating and monitoring these potential hazards is the early detection of cyanobacterial blooms, in real time. Therefore, this paper presents an integrated microflow cytometry platform for label-free phycocyanin fluorescence detection, which can be used for the rapid quantification of low-level cyanobacteria and provide early warning alerts for potential harmful cyanobacterial blooms. An automated cyanobacterial concentration and recovery system (ACCRS) was developed and optimized to reduce the assay volume, from 1000 mL to 1 mL, to act as a pre-concentrator and subsequently enhance the detection limit. The microflow cytometry platform utilizes an on-chip laser-facilitated detection to measure the in vivo fluorescence emitted from each individual cyanobacterial cell, as opposed to measuring overall fluorescence of the whole sample, potentially decreasing the detection limit. By applying transit time and amplitude thresholds, the proposed cyanobacteria detection method was verified by the traditional cell counting technique using a hemocytometer with an R2 value of 0.993. It was shown that the limit of quantification of this microflow cytometry platform can be as low as 5 cells/mL for Microcystis aeruginosa, 400-fold lower than the Alert Level 1 (2000 cells/mL) set by the World Health Organization (WHO). Furthermore, the decreased detection limit may facilitate the future characterization of cyanobacterial bloom formation to better provide authorities with ample time to take the appropriate actions to mitigate human risk from these potentially hazardous blooms.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Mechanical Engineering,Control and Systems Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3