The Use of Novel, Rapid Analytical Tools in the Assessment of the Stability of Tablets—A Pilot Analysis of Expired and Unexpired Tablets Containing Nifuroxazide

Author:

Sarecka-Hujar BeataORCID,Szulc-Musioł BeataORCID,Meisner Michał,Duda Piotr

Abstract

In the analysis of finished pharmaceutical products, numerous innovative analytical techniques are often used, i.e., Raman spectroscopy, scanning electron microscopy, computer microtomography, directional hemispherical reflectance, and hyperspectral analyses. These techniques allow for the identification of changes in solid phases. Many advantages over other techniques can be attributed to these techniques, e.g., they are rapid, non-destructive, and comprehensive. They allow for the identification of changes occurring in solid phases. However, the above-mentioned methods are still not standard procedures in pharmaceutical research. The present study aimed to assess the possible usefulness of total directional hemispherical reflectance (THR), hyperspectral imaging, and computer microtomography to evaluate the stability of tablets containing nifuroxazide during storage. In the study, expired and unexpired coating tablets containing nifuroxazide (n = 10 each) were analyzed. In addition, four unexpired tablets were stored at 40°C over 3 months (stressed tablets). Reflectance was determined with seven wavelength bands from 335 nm to 2500 nm using an SOC-410 Directional Hemispherical Reflectometer (Surface Optics Corporation, San Diego, CA, USA). A Specim IQ hyperspectral camera (Spectral Imaging Ltd., Oulu, Finland) was used with a wavelength range of 400–1030 nm. Tablets were also scanned using X-ray microtomography (Phoenix vǀtomeǀx, GE Sensing & Inspection Technologies GmbH, Wunstorf, Germany). The results indicated that total reflectance was lower in expired tablets than in unexpired tablets in all spectral bands, except for 700–1100 nm and 1700–2500 nm. In turn, the stressed tablets showed higher THR values than expired tablets in all spectral bands, except for 1000–1700 nm. In addition, hyperspectral analysis of the homogeneity of the tablets, as well as X-ray microtomographic analysis of tablet density and coating thickness, indicated that these parameters differed significantly between the analyzed tablets.

Funder

Medical University of Silesia in Katowice

Publisher

MDPI AG

Subject

Process Chemistry and Technology,Chemical Engineering (miscellaneous),Bioengineering

Reference39 articles.

1. Characterization of Pharmaceutical Tablets Using UV Hyperspectral Imaging as a Rapid In-Line Analysis Tool

2. Scanning electron microscopy and X-ray energy dispersive spectroscopy – useful tools in the analysis of pharmaceutical products

3. Biomedical Optics. Selected Issues;Buzalewicz,2011

4. Reflectance quantities in optical remote sensing—definitions and case studies

5. Preliminary analysis of the hemispherical directional reflectance of Alugastrin tablets after 14 days of storage at 40 °C;Meisner;Eur. J. Med. Technol.,2022