Affiliation:
1. Department of Orthopaedic Surgery, Teikyo University School of Medicine, Tokyo 173-8606, Japan
Abstract
Background: There is no consensus on whether mechanical alignment (MA) or kinematic alignment (KA) should be chosen for total knee arthroplasty (TKA) for coronal plane alignment of the knee (CPAK) Type I with a varus arithmetic HKA (aHKA) and apex distal joint line obliquity (JLO). The aim of this study was to investigate whether MA or KA is preferable for soft tissue balancing in TKA for this phenotype. Method: This prospective cohort study included 64 knees with CPAK Type I osteoarthritis that had undergone cruciate-retaining TKA. Using optical tracking software, we simulated implant placement in the Mako system before making the actual bone cut and compared the results between MA and KA. Extension balance (the difference between medial and lateral gaps in extension) and medial balance (the difference in medial gaps in flexion and extension) were examined. These gap differences within 2 mm were defined as good balance. Achievement of overall balance was defined as an attainment of good extension and medial balance. The incidence of balance in each patient was compared with an independent sample ratio test. Results: Compared with the MA group, the KA group achieved better soft tissue balance in extension balance (p < 0.001). A total of 75% of the patients in the KA group achieved overall balance, which was greater than the 38% achieved in the MA group (p < 0.001). Conclusions: In robot-assisted TKA for CPAK Type I osteoarthritis, KA achieved knee balance during extension without soft tissue release in a greater percentage of patients than MA.