Reliability and Validity of Temporal Parameters during the Side Hop Test in Patients after Anterior Cruciate Ligament Reconstruction

Author:

Stitelmann Anna12,Allet Lara3,Armand Stéphane4,Tscholl Philippe15ORCID

Affiliation:

1. Department of Orthopedic Surgery and Traumatology of the Musculoskeletal System, Geneva University Hospitals, 1205 Geneva, Switzerland

2. Geneva School of Health Sciences, HES-SO University of Applied Sciences and Arts Western Switzerland, 1202 Geneva, Switzerland

3. Wallis School of Health Sciences, HES-SO University of Applied Sciences and Arts Western Switzerland, 1950 Sion, Switzerland

4. Kinesiology Laboratory, Geneva University Hospitals and University of Geneva, 1205 Geneva, Switzerland

5. ReFORM IOC Research Centre for Prevention of Injury and Protection of Athlete Health, 4000 Liège, Belgium

Abstract

Background: The side hop test (SHT) measures the number of jumps performed over 30 s. Although this measure has demonstrated its value in clinical practice, the temporal parameters of the SHT allow for a deeper analysis of the execution strategy. The aim of this study is to assess the reliability and construct validity of contact time parameters during the SHT recorded by a video analysis system in anterior cruciate ligament reconstructed (ACLR) patients. Methods: We investigated the reliability (intra-rater, standard error of measurement (SEM), and minimum detectable change (MDC)), discriminant validity (operated (OP) versus non-operated (NOP) side), and convergent validity (relationship with strength and psychological readiness) of SHT contact time parameters, number of valid hops and limb symmetry index (LSI) in 38 ACLR patients. Contact time parameters are presented as mean, standard deviation (SD), and coefficient of variation (CV) of contact time. Results: Intra-tester reliability was good to excellent for all contact time parameters. For discriminant validity, the mean and SD contact times of the OP leg were significantly longer than those of the NOP leg, although the difference was smaller than the SEM and MDC values. The number of valid jumps and CV contact time parameters were not significantly different. Isokinetic quadriceps strength (60°/s) was strongly correlated with mean contact time for both legs. However, psychological readiness was not correlated with any of the contact time parameters. Conclusions: Temporal parameters of the SHT measured on video analysis are valid and reliable parameters to assess the performance strategy of the SHT. The results should be interpreted with caution regarding the SEM and MDC values. Further studies are needed to measure criterion validity, inter-rater reliability, and responsiveness.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3