Differences in Hemodynamic Response to Passive Leg Raising Tests during the Day in Healthy Individuals: The Question of Normovolemia

Author:

Pranskunas Andrius1ORCID,Gulbinaite Egle2,Navickaite Aiste2,Pranskuniene Zivile34

Affiliation:

1. Department of Intensive Care Medicine, Lithuanian University of Health Sciences, Eiveniu g. 2, 50161 Kaunas, Lithuania

2. Faculty of Medicine, Medical Academy, Lithuanian University of Health Sciences, A. Mickeviciaus g. 9, 44307 Kaunas, Lithuania

3. Institute of Pharmaceutical Technologies, Lithuanian University of Health Sciences, Sukileliu pr. 13, 50166 Kaunas, Lithuania

4. Department of Drug Technology and Social Pharmacy, Lithuanian University of Health Sciences, Sukileliu pr. 13, 50166 Kaunas, Lithuania

Abstract

Background: The passive leg-raising (PLR) test was developed to predict fluid responsiveness and reduce fluid overload. However, the hemodynamic response of healthy individuals to the PLR test and how it changes during the day, between the morning and evening, after individuals have consumed food and fluids, has not been profoundly explored. This study aimed to compare the systemic hemodynamic changes in healthy individuals between morning and evening PLR tests. Methods: In this study, the PLR test was performed twice a day. The first PLR test was performed between 08h00 and 09h00 in the morning, while the second PLR test was performed between 20h00 and 21h00 in the evening. Hemodynamic parameters were measured using an impedance cardiography monitor, and a cutoff value of a 10% increase in stroke volume (SV) during the PLR test was used to differentiate between preload responders and non-responders. Results: We included 50 healthy volunteers in this study. When comparing the morning and evening PLR test results, we found no PLR-induced differences in heart rate (−3 [−8–2] vs. −2 [−8–4] beats/min, p = 0.870), SV (11 [5–22] vs. 12 [4–20] mL, p = 0.853) or cardiac output (0.7 [0.2–1.3] vs. 0.8 [0.1–1.4] L/min, p = 0.639). We also observed no differences in the proportion of preload responders during the PLR test between the morning and evening (64% vs. 66%, p = 0.99). However, there was a moderate agreement between the two PLR tests (morning and evening) (kappa = 0.429, p = 0.012). There was a moderate correlation between the changes in SV between the two PLR tests (rs = 0.50, p < 0.001). Conclusion: In young, healthy individuals, we observed no change in the systemic hemodynamic responsiveness to the PLR test between the morning and evening, without restriction of fluid and food intake.

Funder

Research Council of Lithuania

Publisher

MDPI AG

Subject

Paleontology,Space and Planetary Science,General Biochemistry, Genetics and Molecular Biology,Ecology, Evolution, Behavior and Systematics

Reference51 articles.

1. Passive leg raising;Monnet;Intensive Care Med.,2008

2. Passive leg raising: Five rules, not a drop of fluid!;Monnet;Crit. Care,2015

3. Brachial artery diameter changes associated with cardiopulmonary baroreflex activation in humans;London;Am. J. Physiol.,1990

4. Preclinical abnormality of left ventricular performance in patients with insulin-dependent diabetes mellitus;Jermendy;Acta Diabetol. Lat.,1983

5. Passive leg raising induced brachial artery dilation: Is an old technique a simpler method to measure endothelial function?;Kamran;Atherosclerosis,2010