Thermal Analysis of Concrete Blocks and Stack-Bond Prisms under Different Boundary Conditions

Author:

Nalon Gustavo Henrique1ORCID,Ribeiro José Carlos Lopes1,Pedroti Leonardo Gonçalves1ORCID,da Silva Roberto Marcio2ORCID,de Araújo Eduardo Nery Duarte3

Affiliation:

1. Department of Civil Engineering, Universidade Federal de Viçosa, Viçosa 36570-900, Brazil

2. Department of Structural Engineering, Universidade Federal de Minas Gerais, Belo Horizonte 31270-901, Brazil

3. Department of Physics, Universidade Federal de Viçosa, Viçosa 36570-900, Brazil

Abstract

Fire is a significant threat to human lives and the integrity of buildings. To better understand the complex behavior of masonry exposed to high temperatures, thermal analyses were carried out to evaluate the temperature distribution in concrete blocks and stack-bond prisms exposed to high temperature levels. The effects of distinct specimen boundary conditions (restrict or easy access to air circulation inside the voids of the block and prisms) on the thermal response of the masonry materials were investigated. Thersys 2.0 software was used to implement three-dimensional thermal analysis of distinct finite element models. Four-node tetrahedral elements and full integration were used in all models. The modeling approach was validated by experimental data obtained from thermocouples embedded into masonry components. The results indicated that the boundary conditions significantly affected the time required for homogenization of temperature in blocks and prisms. Easy access to air circulation inside the voids of the prisms provided a faster temperature homogenization. In this scenario, the prism reached temperature ranges of (300 ± 0.5% × 300) °C and (600 ± 0.5% × 600) °C after exposure times of 2 h and 2 h 10 min, respectively. When access to air circulation within the voids of the prisms was limited, the same temperature ranges were achieved after exposure times of 5 h 20 min and 6 h, respectively.

Funder

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil

Publisher

MDPI AG

Reference44 articles.

1. Fire Performance of Masonry under Various Testing Methods;Daware;Constr. Build. Mater.,2021

2. Strength and Physical Properties of Sustainable Concrete Masonry at Elevated Temperature: A Review;Yassin;Malays. Constr. Res. J.,2018

3. Masonry Exposed to High Temperatures: Mechanical Behaviour and Properties—An Overview;Russo;Fire Saf. J.,2013

4. Assis, E., and Neto, J. (2020, January 16–19). Analysis of Heat Transfer Mechanisms on Hollow Concrete Masonry Units under Standardized Fire Conditions. Proceedings of the XLI Ibero-Latin-American Congress on Computational Methods in Engineering (CILAMCE), Foz do Iguaçu, Brazil.

5. Nalon, G., Ribeiro, J., Pedroti, L., Silva, R., Araújo, E., Santos, R., and Lima, G. (2023). Review of Recent Progress on the Effects of High Temperatures on the Mechanical Behavior of Masonry Prisms. Infrastructures, 8.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献