Bacterial Contamination of Surgical Instruments Used at the Surgery Department of a Major Teaching Hospital in a Resource-Limited Country: An Observational Study

Author:

Owusu Enid,Asane Francis W.,Bediako-Bowan Antoinette A.,Afutu Emmanuel

Abstract

Surgical instruments, be they disposable or reusable, are essential in any surgical procedure. Reusable surgical instruments should be properly sterilized or disinfected before use. However, the protocols are not always followed accordingly. This results in sterilization and disinfection failures, leading to a possible increase in the incidence of surgical site infections. This observational study report on bacterial contaminants identified instruments used for surgical procedures in a major teaching hospital in a resource-limited country. In total, 207 pre-sterilized surgical instruments and instrument parts used at three units—the general surgical theater, and the gastrointestinal (GI) endoscopy and urology endoscopy (uro-endoscopy) units—within the surgical department were randomly sampled and examined for bacterial contamination. Bacteria isolates were identified, and their antimicrobial susceptibility patterns were determined. Bacteria isolates that were identified included Citrobacter spp., Citrobacter freundii, Bacillus cereus, Staphylococcus hominis, and Staphylococcus aureus. Bacillus cereus was the most predominant bacteria isolated (30/61, 49.1%), and Staphylococcus hominis the least (1/61, 1.6%). In terms of the number of isolates from the three units examined, the uro-endoscopy unit recorded the highest followed by the general surgical theater and the GI endoscopy. However, there was no association between the various units and bacteria isolated, and no significant difference between the number of isolates among the various units (p = 0.9467, χ2 = 0.1095). In this study, even though CFU per device or device part counted was less than 20, bacteria isolated from the instruments used for a surgical procedure is of great concern considering that the setting of the study is a major teaching hospital. Multi-drug resistance was observed in almost all the isolated bacteria. Sterilization processes should be strictly adhered to, taking into consideration the length and temperature in order to reduce the risk of using contaminated instruments in these environments. It is therefore recommended that similar studies should be carried out in surgical departments at different levels of hospitals to ascertain the extent of this problem.

Publisher

MDPI AG

Subject

General Medicine

Reference51 articles.

1. Biochemical and microbial contamination of surgical devices: A quantitative analysis

2. A Practical Guide to Decontamination in Healthcare;McDonnell,2012

3. The Utility of an ATP System for Monitoring the Cleanliness of Surgical Instruments https://multimedia.3m.com/mws/media/720676O/utility-of-an-atp-system-for-monitoring-surgical-instruments.pdf

4. Surgical site infections linked to contaminated surgical instruments

5. Microbial contamination of surgical instruments used for laparotomy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3