Affiliation:
1. Department of Architectural Engineering, Kyung Hee University, Deogyeong-Daero 1732, Yongin 17104, Republic of Korea
Abstract
The adequacy of retrofitting with concrete jacketing is influenced by the bonding between the old section and jacketing section. In this study, five specimens were fabricated, and cyclic loading tests were performed to investigate the integration behavior of the hybrid concrete jacketing method under combined loads. The experimental results showed that the strength of the proposed retrofitting method increased approximately three times compared to the old column, and bonding capacity was also improved. This paper proposed a shear strength equation that considers the slip between the jacketed section and the old section. Moreover, a factor was proposed for considering the reduction in the shear capacity of the stirrup resulting from the slippage between the mortar and stirrup utilized on the jacketing section. The accuracy and validity of the proposed equations were examined through a comparison with the ACI 318-19 design criteria and test results.
Funder
National Research Foundation of Korea
Korean government
Subject
General Materials Science