Affiliation:
1. Department of Architectural Engineering, Chungnam National University, Daejeon 34134, Republic of Korea
2. Department of Architectural Engineering, Gachon University, Seongnam-si 13120, Republic of Korea
Abstract
Specifications are available to quantify flexural performance of steel-fiber reinforced concrete beams with several parameters. Each specification provides different results. This study comparatively evaluates existing flexural beam test standards that are used to evaluate the flexural toughness of SFRC beam specimens. Two standards, EN-14651 and ASTM C1609, were followed to test SFRC beams under the three-point bending test (3PBT) and the four-point bending test (4PBT), respectively. Both normal tensile strength steel fiber (1200 MPa) and high tensile strength steel fiber (1500 MPa) in high-strength concrete were considered in this study. The reference parameters recommended in the two standards, which include equivalent flexural strength, residual strength, energy absorption capacity, and flexural toughness, were compared based on the tensile strength (normal or high) of the steel fiber in high-strength concrete. The 3PBT and 4PBT results indicate that both standard test methods yield similar results to quantify the flexural performance of SFRC specimens. However, unintended failure modes were observed for both standard test methods. The adopted correlation model shows that the flexural performance of SFRC is similar for 3PBTs and 4PBTs, but the residual strength obtained from the 3PBTs tends to be greater than that obtained from 4PBTs with an increase in the tensile strength of steel fiber.
Funder
Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education
Subject
General Materials Science
Reference31 articles.
1. Flexural toughness of hybrid fiber reinforced high-performance concrete under three-point 414 bending;Xiaa;Appl. Mech. Mater.,2013
2. Combined effect of silica fume and steel fiber on the mechanical properties of high strength concretes;Altun;Constr. Build. Mater.,2008
3. (2007). Test Method for Metallic Fibre Concrete. Measuring the Flexural Tensile Strength (Limit of Proportionality (LOP), Residual) (Standard No. EN 14651 + A1).
4. (2002). Test and Design Methods for Steel Fibre Reinforced Concrete. Bending Test, Materials and Structures (Standard No. TC 162-TDF).
5. (2012). Standard Test Method for Flexural Performance of Fiber Reinforced Concrete (Using Beam With Third-Point Loading). American Standard (Standard No. C1609/C1609M-12).
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献