The Performance of Using the Parasympathetic Tone Activity (PTA) Index to Assess Intraoperative Nociception in Cats

Author:

Lima Leonor1,Dos-Santos José Diogo1234,Ribeiro Lénio15,Cabral Patrícia1,Colaço Bruno346ORCID,Martins João12346ORCID

Affiliation:

1. Faculty of Veterinary Medicine, Lusófona University, 1749-024 Lisbon, Portugal

2. Veterinary and Animal Science Research Centre (CECAV), Faculty of Veterinary Medicine, Lusófona University—Lisbon University Center, 1749-024 Lisbon, Portugal

3. Veterinary and Animal Science Research Centre (CECAV), UTAD, 5000-801 Vila Real, Portugal

4. Associate Laboratory for Animal and Veterinary Sciences (AL4AnimalS), 1300-477 Lisbon, Portugal

5. Research Center for Biosciences and Health Technologies (CBIOS), Universidade Lusófona de Humanidades e Tecnologias, 1749-024 Lisbon, Portugal

6. Centre for the Research and Technology of Agro-Environmental and Biological Sciences (CITAB), UTAD, 5000-801 Vila Real, Portugal

Abstract

Background: The monitoring of nociception/antinociception poses a significant challenge during anesthesia, making the incorporation of new tools like the Parasympathetic Tone Activity (PTA) monitor an added value in feline anesthesia. Objectives: To compare the effectiveness and speed of PTA monitoring when compared to heart rate (HR) in detecting surgical stimuli (SS) during the intraoperative period in 49 female cats undergoing ovariectomy (OV). Methods: Instantaneous Parasympathetic Tone Activity (PTAi) values, HR, fR, and non-invasive SAP and MAP were continuously monitored and systematically assessed. The time required for HR (HR time) and PTAi (PTAi time) to reach their minimum peak values following each surgical stimulus was collected at five points for each anaesthetized cat. Each collected surgical stimulus was categorized into 3 groups for statistical analysis: no nociception detection, no hemodynamic reaction and a PTAi > 50 (Nhre); no hemodynamic reaction and a PTAi < 50 (Nhre < 50); and hemodynamic reaction and PTAi < 50 (Hre < 50). Results: PTAi response demonstrated effectiveness in detecting nociception compared to HR. The SS were categorized as 36.1% in the Nhre group, 50% in the Nhre < 50 group, and only 13.9% in the Hre < 50 group. In the Hre < 50 group, PTAi time and HR time had similar speeds in detecting the SS (p = 0.821); however, PTA time was significantly slower in the Nhre < 50 group when compared to the Hre < 50 group (p = 0.001). Conclusions: PTA monitoring may be a useful tool to complement HR monitoring for detecting nociception. PTA monitoring demonstrated a superior diagnostic value compared to HR for detecting nociception in cats undergoing OV and a similar speed to HR in detecting SS when HR increases above 20%. Future studies are needed to understand in a clinical setting the meaning of sympathetic activation/nociception detected using the PTA monitor when the HR increase is not clinically relevant.

Funder

Portuguese Foundation for Science and Technology

Publisher

MDPI AG

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com