A Sub-Picoampere Measurement Algorithm for Use in Dosimetry of Time-Varying Radiation Fields

Author:

Kuć Michał12,Maciak Maciej1ORCID,Tulik Piotr2ORCID

Affiliation:

1. Radiological Metrology and Biomedical Physics Division, National Centre for Nuclear Research, Andrzeja Sołtana 7, 05-400 Otwock, Poland

2. Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics, Warsaw University of Technology, Św. A. Boboli 8, 02-525 Warsaw, Poland

Abstract

Dosimetry based on gas detectors operating in the recombination and saturation region provides unique research opportunities but requires high-quality electrometers with a measuring range below 1 pA (10−12 A). The standard approach in electrometry is to strive to increase the accuracy and precision of the measurement, ignoring the importance of its duration. The article presents an algorithm for the measurement of low current values (from 100 fA) that allows both a fast measurement (with a step of 2.3 ms) and high accuracy (measurement error below 0.1%), depending on the measurement conditions and the expected results. A series of tests and validations of the algorithm were carried out in a measurement system with a Keithley 6517B electrometer and a REM-2 recombination chamber under conditions of constant and time-varying radiation fields. The result of the work is a set of parameters that allow for the optimisation of the operation of the algorithm, maximising the quality of the measurements according to needs and the expected results. The algorithm can be used in low current measurement systems, e.g., for dosimetry of mixed radiation fields using recombination methods and chambers.

Funder

Ministry of Science and Higher Education of the Republic of Poland

Publisher

MDPI AG

Reference26 articles.

1. Dosimetry with a recombination chamber in outdoor conditions and at low dose rates;Zielczynski;Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip.,2003

2. Keithley Instruments (2008). Model 6517B Electrometer User’s Manual, Keithley Instruments, LLC.. 6517B-900-01 Rev., A/Jun.

3. Initial and volume recombination losses in gamma versatile ionization chamber VGIC for gamma ray dosimetry;Fares;Appl. Radiat. Isot.,2021

4. Initial recombination in a parallel-plate ionization chamber exposed to heavy ions;Kanai;Phys. Med. Biol.,1998

5. Dosimetry and microdosimetry of monoenergetic neutrons using recombination chamber—Measurements and Monte Carlo simulations;Maciak;Radiat. Meas.,2022

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3