A Method for Correcting Signal Aberrations in Ultrasonic Indoor Positioning

Author:

Carotenuto Riccardo1ORCID,Iero Demetrio12ORCID,Merenda Massimo12ORCID

Affiliation:

1. Department of Information Engineering, Infrastructure and Energy Sustainable (DIIES), Mediterranea University of Reggio Calabria, 89124 Reggio Calabria, Italy

2. HWA srl, Spin-off Mediterranea University of Reggio Calabria, Via R. Campi II tr. 135, 89126 Reggio Calabria, Italy

Abstract

The increasing focus on the development of positioning techniques reflects the growing interest in applications and services based on indoor positioning. Many applications necessitate precise indoor positioning or tracking of individuals and assets, leading to rapid growth in products based on these technologies in certain market sectors. Ultrasonic systems have already proven effective in achieving the desired positioning accuracy and refresh rates. The typical signal used in ultrasonic positioning systems for estimating the range between the target and reference points is the linear chirp. Unfortunately, it can undergo shape aberration due to the effects of acoustic diffraction when the aperture exceeds a certain limit. The extent of the aberration is influenced by the shape and size of the transducer, as well as the angle at which the transducer is observed by the receiver. This aberration also affects the shape of the cross-correlation, causing it to lose its easily detectable characteristic of a single global peak, which typically corresponds to the correct lag associated with the signal’s time of arrival. In such instances, cross-correlation techniques yield results with a significantly higher error than anticipated. In fact, the correct lag no longer corresponds to the peak of the cross-correlation. In this study, an alternative technique to global peak detection is proposed, leveraging the inherent symmetry observed in the shape of the aberrated cross-correlation. The numerical simulations, performed using the academic acoustic simulation software Field II, conducted using a typical ultrasonic chirp and ultrasonic emitter, compare the classical and the proposed range techniques in a standard office room. The analysis includes the effects of acoustical reflection in the room and of the acoustic noise at different levels of power. The results demonstrate that the proposed technique enables accurate range estimation even in the presence of severe cross-correlation shape aberrations and for signal-to-noise ratio levels common in office and room environments, even in presence of typical reflections. This allows the use of emitting transducers with a much larger aperture than that allowed by the classical cross-correlation technique. Consequently, it becomes possible to have greater acoustic power available, leading to improved signal-to-noise ratio (SNR).

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3