Monolayer Graphene Radiation Sensor with Backend RF Ring Oscillator Transducer

Author:

Tawfik Mohamed W.,Sharaf Abdelhameed,Serry MohamedORCID

Abstract

This paper proposes a new graphene gamma- and beta-radiation sensor with a backend RF ring oscillator transducer employed to convert the change in the graphene resistivity due to ionizing irradiation into a frequency output. The sensor consists of a CVD monolayer of graphene grown on a copper substrate, with an RF ring oscillator readout circuit in which the percentage change in frequency is captured versus the change in radiation dose. The novel integration of the RF oscillator transducer with the graphene monolayer results in high average sensitivity to gamma irradiation up to 3.82 kΩ/kGy, which corresponds to a percentage change in frequency of 7.86% kGy−1 in response to cumulative gamma irradiation ranging from 0 to 1 kGy. The new approach helps to minimize background environmental effects (e.g., due to light and temperature), leading to an insignificant error in the output change in frequency of the order of 0.46% when operated in light versus dark conditions. The uncertainty in readings due to background light was analyzed, and the error in the resistance was found to be of the order of 1.34 Ω, which confirms the high stability and selectivity of the proposed sensor under different background effects. Furthermore, the evolution of the graphene’s lattice defect density due to radiation was observed using Raman spectroscopy and SEM, indicating a lattice defect density of up to 1.780 × 1011/cm2 at 1 kGy gamma radiation, confirming the increase in the graphene resistance and proving the graphene’s sensitivity. In contrast, the graphene’s defect density in response to beta radiation was 0.683 × 1011/cm2 at 3 kGy beta radiation, which is significantly lower than the gamma effects. This can be attributed to the lower p-doping effect caused by beta irradiation in ambient conditions, compared with that caused by gamma irradiation. Morphological analysis was used to verify the evolution of the microstructural defects caused by ionizing irradiation. The proposed sensor monitors the low-to-medium cumulative range of ionizing radiations ranging from 0 to 1 kGy for gamma radiation and 0 to 9 kGy for beta radiation, with high resolution and selectivity, filling the research gap in the study of graphene-based radiation sensors at low-to-medium ionizing radiation doses. This range is essential for the pharmaceutical and food industries, as it spans the minimum range for affecting human health, causing cancer and DNA damage.

Funder

American University in Cairo

Publisher

MDPI AG

Subject

General Materials Science,General Chemical Engineering

Reference37 articles.

1. THz radiation sensors

2. Biomedical sensors of ionizing radiation;Speller;Biomed. Sens.,2010

3. Detecting and Measuring Ionizing Radiation—A Short History;Flakus;IAEA Bull.,1982

4. Beta Radiation

5. Significance of beta-radiation skin burns in Chernobyl patients for the theory and practice of radiopathology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3