Abstract
Segmented cells enable real time visualization of the flow distribution in vanadium redox flow batteries by local current or voltage mapping. The lateral flow of current within thick porous electrodes, however, impairs the local resolution of the detected signals. In this study, the open circuit voltage immediately after the cessation of charge/discharge is used for the mapping of reactant conversion. This quantity is not hampered by lateral flow of current and can be conveniently transformed to the corresponding state of charge. The difference between theoretically calculated and experimentally determined conversion (change in the state of charge) across the electrode is used to determine local variations in conversion efficiency. The method is validated by systematic experiments using electrodes with different modifications, varying current densities and flow configurations. The procedure and the interpretation are simple and scalable to any size of flow cell.
Subject
Electrical and Electronic Engineering,Electrochemistry,Energy Engineering and Power Technology
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献