Assessing Quadriceps Muscle Contraction Using a Novel Surface Mechanomyography Sensor during Two Neuromuscular Control Screening Tasks
Author:
Linderman Shannon E.1, Scarborough Donna Moxley1ORCID, Aspenleiter Ryan2, Stein Hannah S.1, Berkson Eric M.1
Affiliation:
1. Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA 02114, USA 2. FIGUR8, Inc., Boston, MA 02116, USA
Abstract
Electromyography (EMG) is the clinical standard for capturing muscle activation data to gain insight into neuromuscular control, yet challenges surrounding data analysis limit its use during dynamic tasks. Surface mechanomyography (sMMG) sensors are novel wearable devices that measure the physical output of muscle excursion during contraction, which may offer potential easy application to assess neuromuscular control. This study aimed to investigate sMMG detection of the timing patterns of muscle contraction compared to EMG. Fifteen healthy participants (mean age = 31.7 ± 9.1 y; eight males and seven females) were donned with EMG and sMMG sensors on their right quadriceps for simultaneous data capture during bilateral deep squats, and a subset performed three sets of repeated unilateral partial squats. No significant difference in the total duration of contraction was detected by EMG and sMMG during bilateral (p = 0.822) and partial (p = 0.246) squats. sMMG and EMG timing did not differ significantly for eccentric (p = 0.414) and concentric (p = 0.462) phases of muscle contraction during bilateral squats. The sMMG magnitude of quadriceps excursion demonstrated excellent intra-session retest reliability for bilateral (ICC3,1 = 0.962 mm) and partial (ICC3,1 = 0.936 mm, n = 10) squats. The sMMG sensors accurately and consistently provided key quadriceps muscle performance metrics during two physical activities commonly used to assess neuromuscular control for injury prevention, rehabilitation, and exercise training.
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Reference44 articles.
1. Tensiomyography Derived Parameters Reflect Skeletal Muscle Architectural Adaptations Following 6-Weeks of Lower Body Resistance Training;Wilson;Front. Physiol.,2019 2. Đorđević, S., Rozman, S., Zupet, P., Dopsaj, M., and Maffulli, N. (2022). Tensiomyography Allows to Discriminate between Injured and Non-Injured Biceps Femoris Muscle. Biology, 11. 3. Basmajian, J.V., and De Luca, C.J. (1985). Muscles Alive: Their Functions Revealed by Electromyography, Williams & Wilkins. [5th ed.]. 4. Esposito, D., Andreozzi, E., Fratini, A., Gargiulo, G.D., Savino, S., Niola, V., and Bifulco, P. (2018). A Piezoresistive Sensor to Measure Muscle Contraction and Mechanomyography. Sensors, 18. 5. Konrad, P. (2005). The ABC of EMG: A Practical Introduction to Kinesiological Electromyography, Noraxon Inc.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|