Tissue Reaction to Low-Density Polyacrylamide Gel as a Carrier for Microimplants in the Adipose Fin of Rainbow Trout

Author:

Borvinskaya Ekaterina1ORCID,Matrosova Svetlana2,Sukhovskaya Irina23,Drozdova Polina14ORCID,Titov Evgeniy5,Anikienko Inna6,Lubyaga Yulia1ORCID,Gurkov Anton14ORCID,Timofeyev Maxim1ORCID

Affiliation:

1. Institute of Biology, Irkutsk State University, 664025 Irkutsk, Russia

2. Institute of Biology, Ecology and Agricultural Technologies of the Petrozavodsk State University, 185640 Petrozavodsk, Russia

3. Institute of Biology, Karelian Research Centre of Russian Academy of Sciences, 185000 Petrozavodsk, Russia

4. Baikal Research Centre, 664025 Irkutsk, Russia

5. East Siberian Institute of Medical and Ecological Research, 665827 Angarsk, Russia

6. Department of Animal Morphology and Veterinary Sanitation, Irkutsk State Agrarian University n.a. A.A. Ezhevsky, 664038 Molodezhniy, Russia

Abstract

The implantation of optical sensors is a promising method for monitoring physiological parameters of organisms in vivo. For this, suitable hydrogels are required that can provide a biocompatible interface with the organism’s tissues. Amorphous hydrogel is advantageous for administration in animal organs due to its ease of injection compared to resilient analogs. In this study, we investigated the applicability of a semi-liquid 2.5% polyacrylamide hydrogel (PAAH) as a scaffold for fluorescent polyelectrolyte microcapsules (PMs) in rainbow trout. The hydrogel was injected subcutaneously into the adipose fin, which is a small, highly translucent fold of skin in salmonids that is convenient for implanting optical sensors. Using histological methods, we compared tissue organization and in vivo stability of the applied hydrogel at the injection site after administration of uncoated PMs or PMs coated with 2.5% PAAH (PMs-PAAH) for a period of 3 to 14 days. Our results showed that the introduction of PMs into the gel did not have a masking effect, as they were recognized, engulfed, and carried away by phagocytes from the injection site. However, both PMs and PMs-PAAH were found to provoke chronic inflammation at the injection site, although according to cytokine expression in the fish spleen, the irritating effect was local and did not affect the systemic immunity of the fish. Therefore, our study suggests low applicability of 2.5% polyacrylamide as a scaffold for injectable sensors within a timeframe of days.

Funder

Russian Science Foundation

Publisher

MDPI AG

Subject

Polymers and Plastics,Organic Chemistry,Biomaterials,Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3