Integrated Performance Evaluation of Aerogel-Based Fibre-Enhanced Thermal Renders Applied on Building Walls

Author:

Pedroso Marco1ORCID,Silvestre José Dinis1ORCID,Gomes Maria da Glória1ORCID,Hawreen Ahmed123,Bersch Jéssica D.14ORCID,Flores-Colen Inês1ORCID

Affiliation:

1. Civil Engineering Research and Innovation for Sustainability (CERIS), Departamento de Engenharia Civil, Arquitetura e Ambiente (DECivil), Instituto Superior Técnico (IST), Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal

2. Department of Highway and Bridge Engineering, Technical Engineering College, Erbil Polytechnic University, Erbil 44001, Iraq

3. Department of Civil Engineering, College of Engineering, Nawroz University, Duhok 42001, Iraq

4. Núcleo Orientado para a Inovação da Edificação (NORIE), Programa de Pós-Graduação em Engenharia Civil: Construção e Infraestrutura (PPGCI), Universidade Federal do Rio Grande do Sul (UFRGS), Av. Osvaldo Aranha, 99, Porto Alegre 90035-190, Brazil

Abstract

In this work, aerogel renders were enhanced with fibres for use in new building walls, emphasising a Mediterranean climate. The main novelty of the study relies on an integrated evaluation of the aerogel-based fibre-enhanced thermal renders from environmental, energy and economic approaches. Therefore, optimum insulation thicknesses, life cycle savings, payback periods, abiotic depletion potential from fossil fuels (ADP-ff) and global warming potential (GWP) impacts were quantified as a function of the energy consumption. The cost optimisation of aerogel-based renders enabled a reduction from 2477.4 to 1021.7 EUR∙m−3 for the reference formulation, and the sisal-optimised render led to the best-integrated performance. A higher DD* (degree-days equivalent) led to higher optimum thicknesses (the Azores required 0.02 m and 0.01 m and Bragança 0.06 m and 0.03 m for cost-optimised and non-optimised thermal renders with sisal fibre, respectively). The optimum thickness related to the ADP-ff and GWP impacts was higher, 0.04 m for the Azores and 0.09 m for Bragança. A steeper decrease in the annual energy consumption occurred for thermal renders up to 0.02 m in the Azores and 0.04 m in Bragança. Aerogel-based fibre-enhanced thermal renders had benefits, mainly from 600 DD* onwards.

Funder

Fundação para a Ciência e a Tecnologia—FCT

Publisher

MDPI AG

Subject

Polymers and Plastics,Organic Chemistry,Biomaterials,Bioengineering

Reference96 articles.

1. European Commission (2020). Long-Term Low Greenhouse Gas Emission Development Strategy of the European Union and Its Member States.

2. European Parliament (2020). P9_TA(2020)0005 The European Green Deal—European Parliament Resolution of 15 January 2020 on the European Green Deal (2019/2956(RSP)).

3. European Commission (2019, July 15). Energy Performance of EU Buildings, Available online: https://ec.europa.eu/energy/en/topics/en-617ergy-efficiency/energy-performance-of-buildings.

4. Buildings Performance Institute Europe (2011). Europe’s Buildings under the Microscope—A Country-by-Country Review of the Energy Performance of Buildings, BPIE.

5. Aerogel Insulation for Building Applications: A State-of-the-Art Review;Baetens;Energy Build.,2011

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3