Multicenter Experience with Good Manufacturing Practice Production of [11C]PiB for Amyloid Positron Emission Tomography Imaging

Author:

Andersen Anders Bruhn Arndal1,Lehel Szabolcs2,Grove Ebbe Klit3,Langkjaer Niels4ORCID,Fuglø Dan1,Huynh Tri Hien Viet1ORCID

Affiliation:

1. Department of Nuclear Medicine, Copenhagen University Hospital, Herlev and Gentofte, Borgmester Ib Juuls Vej 1, 2730 Herlev, Denmark

2. Department of Clinical Physiology, Nuclear Medicine and PET, Copenhagen University Hospital Rigshospitalet, 2100 Copenhagen, Denmark

3. Department of Nuclear Medicine and PET Centre, Aarhus University Hospital, 8200 Aarhus, Denmark

4. Department of Nuclear Medicine, Odense University Hospital, 5000 Odense, Denmark

Abstract

Alzheimer’s disease (AD) is a neurodegenerative disorder with increasing global prevalence and accounts for over half of all dementia cases. Early diagnosis is paramount for not only the management of the disease, but also for the development of new AD treatments. The current golden standard for diagnosis is performed by positron emission tomography (PET) scans with the tracer [11C]Pittsburg Compound B ([11C]PiB), which targets amyloid beta protein (Aβ) that builds up as plaques in the brain of AD patients. The increasing demand for AD diagnostics is in turn expected to drive an increase in [11C]PiB-PET scans and the setup of new [11C]PiB production lines at PET centers globally. Here, we present the [11C]PiB production setups, experiences, and use from four Danish PET facilities and discuss the challenges and potential pitfalls of [11C]PiB production. We report on the [11C]PiB production performed with the 6-OH-BTA-0 precursor dissolved in either dry acetone or 2-butanone and by using either [11C]CO2 or [11C]CH4 as 11C- precursors on three different commercial synthesis modules: TracerLab FX C Pro, ScanSys, or TracerMaker. It was found that the [11C]CO2 method gives the highest radioactive yield (1.5 to 3.2 GBq vs. 0.8 ± 0.3 GBq), while the highest molar activity (98.0 ± 61.4 GBq/μmol vs. 21.2 to 95.6 GBq/μmol) was achieved using [11C]CH4. [11C]PiB production with [11C]CO2 on a TracerLab FX C Pro offered the most desirable results, with the highest yield of 3.17 ± 1.20 GBq and good molar activity of 95.6 ± 44.2 GBq/μmol. Moreover, all reported methods produced [11C]PiB in quantities suitable for clinical applications, thus providing a foundation for other PET facilities seeking to establish their own [11C]PiB production.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3