Abstract
Bucket elevators are applied in many industries for bulk material handling. One of the main requirements for these devices is their high operational reliability. This applies in particular to power units that must operate continuously without failure. This article presents a comparative assessment of the drive units of two bucket elevators. The vibration intensity of their bearing units was used as the basis for the comparison. The evaluation was carried out using three independent methods based on the vibration velocity analysis: in the time domain, in the frequency domain and using the probabilistic approach.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献