Abstract
The cladded conductor is broadly utilized in engineering fields, such as aerospace, energy, and petrochemical; however, it is vulnerable to thickness loss occurring in the clad layer and nonconductive protection coating due to abrasive and corrosive environments. Such a flaw severely undermines the integrity and safety of the mechanical structures. Therefore, evaluating the thickness loss hidden inside cladded conductors via reliable nondestructive evaluation techniques is imperative. This paper intensively investigates the pulse-modulation eddy current technique (PMEC) for the assessment of thickness loss in a cladded conductor. An analytical model of the ferrite-cored probe is established for analyzing PMEC signals and characteristics of lift-off intersection (LOI) in testing signals. Experiments are conducted for evaluation of the thickness loss in cladded conductors. An inverse scheme based on LOI for estimation of the thickness-loss depth is proposed and further verified. Through simulations and experiments, it is found that the influences of the thickness loss in the clad layer and protective coating on the PMEC signals can be decoupled in virtue of the LOI characteristics. Based on LOI, the hidden thickness loss can be efficiently evaluated without much of a reduction in accuracy by using the PMEC probe for dedicated inspection of the cladded conductor.
Funder
National Natural Science Foundation of China
Fundamental Research Funds for the Central Universities
National Key R&D Program of China
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献