Digital Protocol to Record Occlusal Analysis in Prosthodontics: A Pilot Study

Author:

Risciotti Emanuele1,Squadrito Nino2,Montanari Daniele2,Iannello Gaetano3,Macca Ugo4,Tallarico Marco5ORCID,Cervino Gabriele6,Fiorillo Luca678ORCID

Affiliation:

1. Private Practice, 20145 Milan, Italy

2. Private Practice, 16121 Genova, Italy

3. Private Practice, 16036 Genova, Italy

4. Private Practice, 96100 Siracusa, Italy

5. School of Dentistry, University of Sassari, 07100 Sassari, Italy

6. Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, 98122 Messina, Italy

7. Department of Dental Cell Research, Dr. D. Y. Patil Dental College and Hospital, Dr. D. Y. Patil Vidyapeeth, Sant-Tukaram Nagar, Pimpri, Pune 411018, India

8. Multidisciplinary Department of Medical-Surgical and Odontostomatological Specialties, University of Campania “Luigi Vanvitelli”, 80121 Naples, Italy

Abstract

Background: Digital technologies enable the accurate replication of occlusion, which is pivotal for stability in maximum intercuspation and dynamic occlusion. CAD softwares generates standardized occlusal morphologies requiring significant adjustments. The consideration of individual mandibular movements during restoration leads to better functional integration. This pilot study evaluates the efficacy of a novel, fully digital protocol for occlusal analysis recording in prosthodontics. Methods: Patients needing single or multiple metal-free restorations were included. Teeth underwent horizontal finish line preparation, while restorations on implants were either directly screwed or used multi-unit abutments. A digital impression (Trios 3 Intraoral Scanner) captured the mouth’s elements. Dynamic occlusion was recorded via Patient Specific Motion (PSM). After the placement and functionalization of temporary restorations, subsequent scans included various elements, and CAD software (Dental system) was used for the restoration design. Restorations were milled in monolithic zirconia, pressed from CAD/CAM-milled wax, and sintered. Results: An evaluation of 52 restorations in 37 patients indicated high accuracy in restorations manufactured via the fully digital workflow. Monolithic zirconia was predominantly used. Subtractive (17.3%) and additive (7.7%) occlusal adjustments were mainly chairside. Conclusion: This study underscores the efficacy of meticulous verification measures and a centric contact system in reducing the need for clinical occlusal refinements in prosthetic restorations.

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3