Flax fibre has been used to reinforce concrete composite, but its dynamic properties have not been thoroughly studied. This study investigates the dynamic splitting tensile properties of plain concrete (PC) confined by flax-fibre-reinforced polymer (FFRP) and glass-fibre-reinforced polymer (GFRP). The dynamic splitting tensile tests were carried out on PC, FFRP-PC, and GFRP-PC cylinder specimens by the high-speed servo-hydraulic machine, with the impact-induced strain rates ranging from 0.1 to 58 s−1. The effect of the FRP confinement, FRP thickness and strain rate on the dynamic splitting tensile behaviour were assessed. The results indicated that similar confinement effectiveness of FFRP and GFRP is observed. The dynamic tensile strength of 1- and 2-layer FFRP-PC increased by 29% and 67%, and the one- and two-layer GFRP-PC increased by 32% and 84%, respectively. FFRP-PC and GFRP-PC cylinders showed less sensitivity to the strain rate compared with PC. The empirical relationship between the tensile DIF and strain rate for PC, FFRP-PC and GFRP-PC was proposed based on experimental data. The proposed model was developed to predict the dynamic splitting tensile strength. The results suggested the potential of FFRP composites applied into concrete structures under extreme dynamic loadings.