Abstract

Airborne infrared optical systems equipped with multiple cooled infrared cameras are commonly utilized for quantitative radiometry and thermometry measurements. Radiometric calibration is crucial for ensuring the accuracy and quantitative application of remote sensing camera data. Conventional radiometric calibration methods that consider internal stray radiation are usually based on the assumption that the entire system is in thermal equilibrium. However, this assumption leads to significant errors when applying the radiometric calibration results in actual mission scenarios. To address this issue, we analyzed the changes in optical temperature within the system and developed a simplified model to account for the internal stray radiation in the non-thermal equilibrium state. Building upon this model, we proposed an enhanced radiometric calibration method, which was applied to the absolute radiometric calibration procedure of the system. The radiometric calibration experiment, conducted on the medium-wave channel of the system within a temperature test chamber, demonstrated that the proposed method can achieve a calibration accuracy exceeding 3.78% within an ambient temperature range of −30 °C to 15 °C. Additionally, the maximum temperature measurement error was found to be less than ±1.01 °C.

Funder

National Key R&D Program of China

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference26 articles.

1. Calibration method for IR channel of dual-band long-range airborne camera;Petrushevsky;Proceedings of the Infrared Technology and Applications XXX,2004

2. High-resolution long-range oblique IR imaging from an airborne platform;Petrushevsky;Proceedings of the Electro-Optical and Infrared Systems: Technology and Applications III,2006

3. The Goodrich 3rd generation DB-110 system: Operational on tactical and unmanned aircraft;Iyengar;Proceedings of the Airborne Intelligence, Surveillance, Reconnaissance (ISR) Systems and Applications III,2006

4. EO/IR dual-band reconnaissance system DB-110;Sementelli;Proceedings of the Airborne Reconnaissance XIX,1995

5. Wyatt, C. (2012). Radiometric Calibration: Theory and Methods, Elsevier.