Abstract
Objectives: Few studies have evaluated the marginal fit of computer-aided design—computer-aided manufacturing (CAD-CAM) monolithic zirconia crowns fabricated through completely digital workflow; however, the internal fit of these restorations is not well known. The purpose of this in vitro study was to evaluate the marginal and internal fit of monolithic zirconia crowns fabricated by using digital workflow, including intraoral scanner (IOS) scans, and compare the results to those of a semi-digital workflow, which combined conventional impressions, poured casts, and extraoral scanner (EOS) scanning. Materials and methods: A typodont right mandibular first molar was prepared for a complete-coverage ceramic crown and scanned using an IOS. The conventional impressions of the preparation were also made, and stone casts were poured and scanned by using an EOS. Virtual models were generated for both workflows, and identical virtual anatomic contour crowns were designed using CAD software. Monolithic zirconia crowns were fabricated for both IOS (ZI; n = 10) and EOS (ZE; n = 10) groups. The silicon replica technique was used to evaluate the marginal and internal fit of the crowns. Measurements were made at 13 points on buccolingual and mesiodistal cross-sections per specimen with a ×6.5 to ×50 zoom stereo microscope. The results from both groups were statistically compared using the Independent Samples t-tests and the Mann–Whitney U test (α = 0.05). Results: Mean gap values at all measurement locations for ZE were significantly higher than those for ZI (p ≤ 0.002). Overall mean values ranged between 29 and 43 µm (median: 28–42 µm) for ZI and 42 and 75 µm (median: 43–77 µm) for ZE. Conclusion: Completely digital workflow through intraoral scans provided significantly better marginal and internal fit for CAD-CAM monolithic zirconia crowns compared with the semi-digital workflow, where stone casts obtained from conventional impressions were scanned with an EOS. Yet, both workflows provided an acceptable marginal and internal fit for CAD-CAM monolithic zirconia molar crowns (<120 µm). Clinical Relevance: Completely digital workflow using IOS scans may be advantageous for the fabrication of CAD-CAM monolithic zirconia crowns as favorable results can be obtained with less material waste and potentially shortened overall treatment time as the impression files can be transferred to the production facility electronically. The results need to be corroborated with clinical studies.
Funder
Dicle University Scientific Research Fund
Subject
General Earth and Planetary Sciences,General Environmental Science
Reference62 articles.
1. The current state of chairside digital dentistry and materials;Blatz;Dent. Clin. N. Am.,2019
2. Accuracy of intraoral scanners: A systematic review of influencing factors;Abduo;Eur. J. Prosthodont. Restor. Dent.,2018
3. Mangano, F., Gandolfi, A., Luongo, G., and Logozzo, S. (2017). Intraoral scanners in dentistry: A review of the current literature. BMC Oral Health, 17.
4. Intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: A systematic review;Siqueira;Clin. Oral Investig.,2021
5. Influence of tooth preparation design and scan angulations on the accuracy of two intraoral digital scanners: An in vitro study based on 3-dimensional comparisons;Ammoun;J. Prosthodont.,2020
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献