Evaluation of the Transient Overvoltages of HVDC Transmission Lines Caused by Lightning Strikes

Author:

Zalhaf Amr S.ORCID,Zhao Ensheng,Han Yang,Yang Ping,Almaliki Abdulrazak H.ORCID,Aly Reda M. H.

Abstract

High-voltage direct-current (HVDC) transmission systems are considered an outstanding solution due to high electrical losses emerging from long-distance transmission. However, HVDC transmission lines (TLs) are vulnerable to lightning strikes. In this work, the Yunnan-Guizhou 500 kV HVDC transmission system is used as a case study to evaluate the impact of lightning strikes on DC-TL overvoltages, as no research studies have been conducted to assess the lightning transient behavior of DC-TLs. A comprehensive investigation of the 500 kV DC-TL transient performance during lightning strikes is performed, taking into account different technical aspects that have not been studied in detail by previous researchers. Additionally, analysis of the back-flashover phenomenon has not been conducted well in previous work, and results on the effect of changing the lightning strike current peak and tower grounding resistance on shielding-failure flashover are quite limited. The distributed-parameter model is used to represent the DC-TL using the electromagnetic transients program (EMTP), considering real parameters of shielding wires and DC towers to study the lightning impact in the case of back-flashover and shielding-failure phenomena. Lightning strike is applied to the shielding wire, and the impact of increasing the peak value of lightning current is investigated on the back-flashover occurrence. Moreover, the influence of tower grounding resistance variation on the transient overvoltages across the tower body and back-flashover phenomenon is evaluated. From the simulation results, increasing the lightning current peak and grounding resistance results in higher overvoltages across the tower body, which increases the probability of back-flashover. Additionally, the shielding failure of the TL is assumed, and the variation impact of the lightning current peak and grounding resistance on shielding-failure flashover is investigated. The results show that the impact of the lightning current peak has a more significant impact than the grounding resistance in the case of shielding-failure flashover.

Funder

Taif University

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3