Motion Correction for Brain MRI Using Deep Learning and a Novel Hybrid Loss Function

Author:

Zhang Lei1,Wang Xiaoke1,Rawson Michael2,Balan Radu2ORCID,Herskovits Edward H.1ORCID,Melhem Elias R.1,Chang Linda1,Wang Ze1ORCID,Ernst Thomas1

Affiliation:

1. Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, 670 W. Baltimore Street, HSF-III, Baltimore, MD 21201, USA

2. Department of Mathematics and Center for Scientific Computation and Mathematical Modeling, University of Maryland, College Park, MD 20742, USA

Abstract

Purpose: Motion-induced magnetic resonance imaging (MRI) artifacts can deteriorate image quality and reduce diagnostic accuracy, but motion by human subjects is inevitable and can even be caused by involuntary physiological movements. Deep-learning-based motion correction methods might provide a solution. However, most studies have been based on directly applying existing models, and the trained models are rarely accessible. Therefore, we aim to develop and evaluate a deep-learning-based method (Motion Correction-Net, or MC-Net) for suppressing motion artifacts in brain MRI scans. Methods: A total of 57 subjects, providing 20,889 slices in four datasets, were used. Furthermore, 3T 3D sagittal magnetization-prepared rapid gradient-echo (MP-RAGE) and 2D axial fluid-attenuated inversion-recovery (FLAIR) sequences were acquired. The MC-Net was derived from a UNet combined with a two-stage multi-loss function. T1-weighted axial brain images contaminated with synthetic motions were used to train the network to remove motion artifacts. Evaluation used simulated T1- and T2-weighted axial, coronal, and sagittal images unseen during training, as well as T1-weighted images with motion artifacts from real scans. The performance indices included the peak-signal-to-noise ratio (PSNR), the structural similarity index measure (SSIM), and visual reading scores from three blinded clinical readers. A one-sided Wilcoxon signed-rank test was used to compare reader scores, with p < 0.05 considered significant. Intraclass correlation coefficients (ICCs) were calculated for inter-rater evaluations. Results: The MC-Net outperformed other methods in terms of PSNR and SSIM for the T1 axial test set. The MC-Net significantly improved the quality of all T1-weighted images for all directions (i.e., the mean SSIM of axial, sagittal, and coronal slices improved from 0.77, 0.64, and 0.71 to 0.92, 0.75, and 0.84; the mean PSNR improved from 26.35, 24.03, and 24.55 to 29.72, 24.40, and 25.37, respectively) and for simulated as well as real motion artifacts, both using quantitative measures and visual scores. However, MC-Net performed poorly for images with untrained T2-weighted contrast because the T2 contrast was unseen during training and is different from T1 contrast. Conclusion: The proposed two-stage multi-loss MC-Net can effectively suppress motion artifacts in brain MRI without compromising image quality. Given the efficiency of MC-Net (with a single-image processing time of ~40 ms), it can potentially be used in clinical settings.

Funder

NIH

NSF

Simons Foundation Fellowship

Publisher

MDPI AG

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3