Abstract
To make a better application of the self-excited oscillation jet, a compound organ–Helmholtz oscillation nozzle (OH nozzle) was designed to generate better pulse effects in the present study. The effects of geometric parameters on pressure characteristics of self-excited oscillation jets were investigated experimentally. The geometric parameters of OH nozzles were determined based on the design principle of the organ-pipe and Helmholtz nozzles. Various types of OH nozzles were tested to obtain the relationship between oscillation pressure and geometric parameters. Experimental results showed that some structural parameters are sensitive to the pump pressure, while others are not. The optimum geometric optimum parameters were obtained based on experimental results. The peak pressure and pressure pulsation amplitude are closely related to the target distance. The peak pressure decreases sharply with target distance at first and decreases with a further increase of the target distance. The peak pressure becomes stable beyond a certain range of target distance. With the increase of the target distance, the pressure pulsation amplitude increases at first and then decreases. The optimum target distance was determined based on experimental results to achieve better pulsation performance and has a value of 20 mm in the present study.
Funder
the National Natural Science Foundation of China
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献