Abstract
In the paper, a model of a three-phase frequency-controlled induction electric drive has been developed in Simulink Matlab 2019 (MathWorks, Natick, MA, USA). This model is mathematically converted into a two-phase model by transforming equations. It is proposed to compensate the voltage drop in the power system during start-up operation under load by using supercapacitors as a buffer power source. A block of supercapacitors was calculated. Simulation modeling was performed at a different voltage than the network. The diagrams of the transient processes occurring in the electric drive when the power supply is changed were prepared. It was found that such a principle of implementing an additional source of electric energy allows to start induction electric drives in areas remote from industrial networks without significantly affecting their static and dynamic characteristics.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献