The Influence of a Manifold Structure on the Measurement Results of a PIV Flowmeter

Author:

Chen Huiyu12,Qiu Yilong12,Wang Hui12,Gao Mengjie3

Affiliation:

1. Natural Gas Research Institute, PetroChina Southwest Oil & Gas Field Company, Chengdu 610213, China

2. Key Laboratory of Natural Gas Quality Control and Energy Measurement for State Market Regulation, Chengdu 610213, China

3. China Petroleum Engineering & Construction Corp. Southwest Company, Chengdu 610041, China

Abstract

The application of particle image velocimetry (PIV) technology for monitoring natural gas flow is a new method of flow measurement. Since the principle of this technology was proposed, there are still some potential issues. This article investigates the influence of a manifold structure on the measurement results of a PIV flowmeter. A comparison is performed between concentric and eccentric manifold structures, using a circular straight pipe as reference, in terms of the measurement error of the PIV flowmeter and the internal flow state of the natural gas. The results demonstrate that the manifold structure significantly affects the measurement reliability of the PIV flowmeter, especially the eccentric manifold structure. Under flow conditions ranging from 100 to 600 m3/h, the maximum measurement errors caused by the concentric and eccentric manifold structures are 2.49% and 3.05%, respectively, which show a noticeable increase compared to the maximum measurement error of 2.08% observed for the circular straight pipe. Additionally, the influence of the manifold structure on the downstream flow field is also evident, as the eccentric manifold structure increases the turbulence intensity of the downstream fluid by nearly twofold. The addition of a rectifier can effectively improve the flow state and enhance the measurement reliability of the PIV flowmeter. For the concentric manifold structure under the condition of a 600 m3/h flow rate, the inclusion of a rectifier produces highly accurate measurement results, similar to those obtained by an ultrasonic flowmeter, with an error value close to zero. This study provides technical support for further promoting the practical application of PIV flowmeters.

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3