Clinical Evaluation of Time Efficiency and Fit Accuracy of Lithium Disilicate Single Crowns between Conventional and Digital Impression

Author:

Park Ji-Su,Lim Young-JunORCID,Kim BongjuORCID,Kim Myung-JooORCID,Kwon Ho-BeomORCID

Abstract

The purpose of this study was to demonstrate the time-efficiency and the clinical effectiveness of chairside-fabricated lithium disilicate single crowns by digital impressions compared to the conventional method. Thirteen patients requiring a single crown on the maxillary or mandibular premolar or first molar were assigned as study subjects. The impressions were obtained using the conventional method and two digital methods with intraoral scanners: AEGIS.PO (Digital Dentistry Solution, Seoul, Korea) and CEREC Omnicam (Sirona, Bensheim, Germany). Two types of lithium disilicate single crowns were obtained; a reference crown (by conventional workflow) and a chairside crown (by digital workflow). The total time taken for fabricating the chairside crown was recorded. The replica technique was performed to compare the marginal and internal fit of the two types of crowns. In addition, accuracy of the intraoral scanners was evaluated by the best-fit alignment method. The difference between the groups was analyzed using the two-tailed paired t-test or one-way ANOVA, followed by the Student–Newman–Keuls test for multiple comparisons. Statistical significance was accepted at p < 0.05 for all statistical tests. The time required to obtain the impressions by the AEGIS (7:16 ± 1:50 min:s) and CEREC (7:29 ± 2:03 min:s) intraoral scans was significantly lower than the conventional method (12:41 ± 1:16 min:s; p < 0.001). There was no significant difference between the intraoral scanners. The total working time to fabricate the chairside crown averaged 30:58 ± 4:40 min:s. The average marginal gap was not significantly different between the reference (107.86 ± 42.45 µm) and chairside (115.52 ± 38.22 µm) crowns (p > 0.05), based on results of replica measurement. The average internal gaps were not significantly different. The average value of the root mean square between the AEGIS (31.7 ± 12.3 µm) and CEREC (32.4 ± 9.7 µm) scans was not significantly different (p > 0.05). Intraoral scans required a significantly shorter impression time than the conventional method, and it was possible to fabricate a lithium disilicate crown in a single visit. There were no statistically significant differences in the fit of the restorations and accuracy of the intraoral scanners compared to the conventional workflow.

Publisher

MDPI AG

Subject

General Materials Science

Reference58 articles.

1. Dentistry in the digital age: An update;Schoenbaum;Dent. Today,2012

2. Time-Efficiency Analysis Comparing Digital and Conventional Workflows for Implant Crowns: A Prospective Clinical Crossover Trial

3. Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes

4. Digital dentistry: Innovation for restorative treatment;Fasbinder;Compend. Contin. Educ. Dent.,2010

5. Materials for chairside CAD/CAM restorations;Fasbinder;Compend. Contin. Educ. Dent.,2010

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3