Determination of Performance of Different Pad Materials and Energy Consumption Values of Direct Evaporative Cooler

Author:

Jakubowski Tomasz1ORCID,Boyacı Sedat2ORCID,Kocięcka Joanna3ORCID,Atılgan Atılgan4ORCID

Affiliation:

1. Department of Machine Operation, Ergonomics and Production Processes, Faculty of Production and Power Engineering, University of Agriculture in Krakow, 30-059 Krakow, Poland

2. Department of Biosystems Engineering, Faculty of Agriculture, Kırşehir Ahi Evran University, 40100 Kırşehir, Turkey

3. Department of Land Improvement, Environmental Development and Spatial Management, Poznan University of Life Sciences, 60-649 Poznań, Poland

4. Department of Biosystems Engineering, Faculty of Engineering, Alanya Alaaddin Keykubat University, 07425 Alanya, Turkey

Abstract

The purpose of this study is to determine the performances of luffa and greenhouse shading netting (which can be used as alternatives to commercial cellulose pads, that are popular for cooling greenhouses), the contribution of external shading to the evaporative cooling performance, and the energy consumption of the direct evaporative cooler. In this experiment, eight different applications were evaluated: natural ventilation (NV), natural ventilation combined with external shading net (NV + ESN), cellulose pad (CP), cellulose pad combined with external shading net (CP + ESN), luffa pad (LP), luffa pad combined with external shading net (LP + ESN), shading net pad (SNP), and shading net pad combined with external shading net (SNP + ESN). The cooling efficiencies of CP, CP + ESN, LP, LP + ESN, SNP, and SNP + ESN were found to be 37.6%, 45.0%, 38.9%, 41.2%, 24.4%, 29.1%, respectively. Moreover, their cooling capacities were 2.6 kW, 3.0 kW, 2.8 kW, 3.0 kW, 1.7 kW, 2.0 kW, respectively. The system water consumption values were 2.9, 3.1, 2.8, 3.2, 2.4, 2.4 l h−1, respectively. The performance coefficients of the system were determined to be 10.2, 12.1, 11.3, 11.9, 6.6, 7.8. The system’s electricity consumption per unit area was 0.15 kWh m−2. As a result of the study, it was determined that commercially used cellulose pads have advantages over luffa and shading net materials. However, luffa pads can be a good alternative to cellulose pads, considering their local availability, initial cost, cooling efficiency, and capacity.

Publisher

MDPI AG

Reference57 articles.

1. Sharma, A.K., and Salokhe, V.M. (2006). Greenhouse Technology and Application, Agrotech Publishing Academy. [1st ed.].

2. Comparative thermoeconomic assessment of renewable-driven hybrid-cooled sustainable greenhouses for subtropical regions;Abedrabboh;Energy Convers. Manag.,2024

3. Enhancing the evaporative cooling performance of fan-pad system using alternative pad materials and water film over the greenhouse roof;Helmy;Agric. Eng. Int. CIGR J.,2013

4. Experimental performance of evaporative cooling pad systems in greenhouses in humid subtropical climates;Xu;Appl. Energy,2015

5. von Zabeltitz, C. (2011). Integrated Greenhouse Systems for Mild Climates, Springer.