Abstract
In this study, a dispersive solid-phase extraction (DSPE) pretreatment procedure using zeolite H-Beta as a sorbent was exploited for the determination of eight neonicotinoids in bottled water and honey products based on ultra-high-performance liquid chromatography–tandem mass spectrometry analysis. The zeolite H-Beta was demonstrated to be a suitable sorbent for neonicotinoid insecticides, even after 10 recycles of reuse. The method performance was evaluated by the linearity (R2 ≥ 0.998), recovery (71–108%), precision (0.1–7.8%), limit of detection (0.05–0.1 ng/mL) and limit of quantification (0.1–0.2 ng/mL), which suggested excellent stability and high sensitivity with the use of the DSPE procedure. The method was further successfully applied in the test of neonicotinoid insecticides in 34 samples. Zeolite H-Beta shows promise as an efficient and practical material for monitoring neonicotinoid insecticides in bottled water and multiplex honey matrices.
Funder
Shanghai Agriculture Applied Technology Development Program, China
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献