Assessment of Low-Density Force Myography Armband for Classification of Upper Limb Gestures

Author:

Rehman Mustafa Ur1ORCID,Shah Kamran12,Haq Izhar Ul1,Iqbal Sajid3,Ismail Mohamed A.2ORCID,Selimefendigil Fatih2

Affiliation:

1. Department of Mechatronics Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan

2. Department of Mechanical Engineering, King Faisal University, Al-Hofuf 31982, Saudi Arabia

3. Department of Information Systems, King Faisal University, Al-Hofuf 31982, Saudi Arabia

Abstract

Using force myography (FMG) to monitor volumetric changes in limb muscles is a promising and effective alternative for controlling bio-robotic prosthetic devices. In recent years, there has been a focus on developing new methods to improve the performance of FMG technology in the control of bio-robotic devices. This study aimed to design and evaluate a novel low-density FMG (LD-FMG) armband for controlling upper limb prostheses. The study investigated the number of sensors and sampling rate for the newly developed LD-FMG band. The performance of the band was evaluated by detecting nine gestures of the hand, wrist, and forearm at varying elbow and shoulder positions. Six subjects, including both fit and amputated individuals, participated in this study and completed two experimental protocols: static and dynamic. The static protocol measured volumetric changes in forearm muscles at the fixed elbow and shoulder positions. In contrast, the dynamic protocol included continuous motion of the elbow and shoulder joints. The results showed that the number of sensors significantly impacts gesture prediction accuracy, with the best accuracy achieved on the 7-sensor FMG band arrangement. Compared to the number of sensors, the sampling rate had a lower influence on prediction accuracy. Additionally, variations in limb position greatly affect the classification accuracy of gestures. The static protocol shows an accuracy above 90% when considering nine gestures. Among dynamic results, shoulder movement shows the least classification error compared to elbow and elbow–shoulder (ES) movements.

Funder

Deanship of Scientific Research, Vice Presidency for Graduate studies and Scientific Research, King Faisal University, Saudi Arabia

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference57 articles.

1. Biryukova, E.V., and Yourovskaya, V. (1994). Advances in the Biomechanics of the Hand and Wrist, Springer.

2. Differences in myoelectric and body-powered upper-limb prostheses: Systematic literature review;Carey;J. Rehabil. Res. Dev.,2015

3. Michelangelo 03-A versatile hand prosthesis, featuring superb controllability and sophisticated bio mimicry;Puchhammer;J. Rehabil. Res. Dev.,2008

4. Medynski, C., and Rattray, B. (2011, January 14–19). Bebionic prosthetic design. Proceedings of the 2011 MyoElectric Controls/Powered Prosthetics Symposium, Fredericton, NB, Canada.

5. Prosthetic hands from touch bionics;Connolly;Ind. Robot.,2008

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3