Parametric Study and Optimization of No-Blocking Heliostat Field Layout

Author:

Derbal Dhikra1,Abderrezak Abdallah1,Chehaidia Seif Eddine2ORCID,Amin Majdi T.3,Mosaad Mohamed I.45ORCID,Abdul-Fattah Tarek A.6

Affiliation:

1. Research Laboratory of Industrial Risks, Non-Destructive Control and Operating Safety, Mechanical Engineering Department, Badji Mokhtar Annaba University, Annaba 23000, Algeria

2. Département de Génie Mécanique, Ecole Nationale Polytechnique de Constantine (ENPC), Constantine 25000, Algeria

3. Mechanical Engineering Technology, Yanbu Industrial College (YIC), Royal Commission Yanbu Colleges & Institutes, Alnahdah, Yanbu Al Sinaiyah, Yanbu 46452, Saudi Arabia

4. Electrical Engineering Department, Faculty of Engineering, Damietta University, Damietta 34511, Egypt

5. Electrical & Electronics Engineering Technology Department, Yanbu Industrial College (YIC), Royal Commission Yanbu Colleges & Institutes, Alnahdah, Yanbu Al Sinaiyah, Yanbu 46452, Saudi Arabia

6. Department of Engineering Physics and Mathematics, Faculty of Engineering, Zagazig University, Zagazig 44519, Egypt

Abstract

Generating electric power using solar thermal systems is effective, particularly for countries with high solar potential. In order to decide on a relevant location to implement the solar tower plant and develop the mathematical model of a no-blocking heliostat field, a meteorological assessment was discussed in this paper. In addition, a parametric study was examined to evaluate the effect of the designed parameters (heliostat size, heliostat height from the ground, tower height, receiver aperture, and the minimum radius) on the solar field’s performance. The preliminary solar field was then compared to the final design using the optimal design parameters. The obtained results showed that “Tamanrasset City” satisfied the necessary conditions for implementing a solar tower plant. According to preliminary solar field generation, no heliostat blocked its neighbor with a blocking efficiency of 100%. An analysis of its performance revealed that the optimized solar field would be capable of producing 15, 6571 MW, operating at an optical efficiency of 76.95%, and the enhancement rate of both efficiency and power output was 8.1%.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Optical Efficiency Optimization Algorithm for Heliostat Field in Solar Power Tower;2024 IEEE 7th International Electrical and Energy Conference (CIEEC);2024-05-10

2. Artificial Neural Network MPPT Based Lead Acid Battery Charge Controller for Isolated Photovoltaic System;2023 International Conference on Electrical Engineering and Advanced Technology (ICEEAT);2023-11-05

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3