Abstract

Transmission towers are prone to collapse under strong wind load, resulting in significant economic losses. In order to investigate the collapse mechanism and failure modes of the transmission tower under strong wind load and whether the wind vibration factor can greatly reflect the increasing effect of the fluctuating wind, the finite element method (FEM) is utilized to analyze the ultimate bearing capacity of a typical 220 kV transmission tower. The results show that the collapse of the tower under strong wind loads is usually due to the buckling of the leg members. When the reference wind speed is equal to 27 m/s, a small part of the main leg members reaches their yield strength, while the diagonal members are still in the elastic range, and the deformation of the transmission tower is unapparent at this wind speed. When reference wind speed is equal or greater than 30 m/s, the growing variety of main legs is totally into the plastic yield stage, and the overall deformation of this tower is visible. Therefore, the transmission tower is collapsed due to the large deformation caused by the elastic-plastic buckling of leg members. Based on the aforementioned study, a finite element model involving three transmission towers and four span transmission lines is established to analyze the dynamic response of the tower-line system below fluctuating wind. Results show that the wind-induced coefficients designed by current code not only notably satisfy the stress response of tower components subjected to fluctuating wind loads in the elastic phase but also accurately assess the collapse displacement of the transmission tower. The increasing effect of displacement on the top tower under fluctuating wind, unfortunately, could not considerably reply with the investigated factor, and the load-carrying capacity of the transmission tower in the plastic phase can be overestimated by static calculation results.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3