Abstract
A variety of modulation strategies for suppressing output common-mode voltage (CMV) of indirect matrix converters (IMC) have been proposed, but most of them mainly reduce the peak of CMV by 42.3%. The frequency-domain characteristics of CMV have not been deeply analyzed. In order to improve the theory of frequency-domain characteristics of output common-mode voltage of IMC, this paper proposed a common-mode frequency domain analysis of five common-mode voltage peak suppression modulation methods for IMC. The common-mode voltage spectrum corresponding to the five modulation methods is obtained by the triple Fourier series, and the variation laws of the output common-mode components of the five modulation methods under different modulation indexes are compared and analyzed. By comparing and analyzing the low-frequency amplitude characteristics and high-frequency amplitude characteristics of five modulation methods, the suppression performance of the five modulation methods is evaluated. Finally, experiments verify the correctness of the theoretical analysis of the frequency domain characteristics of the output common-mode voltage of the indirect matrix converter.
Funder
Tianjin Natural Science Foundation
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction